{"trade":"elevator","week":"2016-W18","weekStart":"2016-05-02","weekEnd":"2016-05-08","fetchedAt":"2026-08-04T07:13:35.936Z","source":{"dataset":"ydr8-5enu","api":"https://data.cityofchicago.org/resource/ydr8-5enu.json","page":"https://data.cityofchicago.org/Buildings/Building-Permits/ydr8-5enu"},"ok":true,"error":null,"truncated":false,"permits":[{"permit":"100647119","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"3301 W ARTHINGTON ST","workDescription":"INSTALL THREE (3) ELEVATORS; #S1 5000LB.CAP, 150FPM,7-LANDINGS(6-FRONT/1-REAR)6-8MM 4:1 HOIST ROPES. #P1 & #P2 2000LB.CAP,200FPM,7-LANDINGS(6FRONT/1-REAR) 5-8MM 2:1 HOIST ROPES. PURSUANT TO PLANS SUBMITTED.","reportedCost":450000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100647119"},{"permit":"100648314","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"6411 N ROCKWELL ST","workDescription":"INSTALLATION OF TWO (2) #3 & #4, 2500LB.CAP, 150FPM, 8-FLOORS, 3-30MM, 2:1 TRACTION PASENGER ELEVATORS. PURSUANT TO PLANS SUBMITTED.","reportedCost":239567,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100648314"},{"permit":"100648311","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"222 W MERCHANDISE MART PLZ","workDescription":"ADD TWO (2) REAR OPENINGS AT THE 10TH & 11TH FOR 8000LB.CAP, 19 FRONT & REAR OPENINGS, EWGT, C.S. FREIGHT ELEVATOR #25. PURSUANT TO SCOPE OF WORK SUBMITTED. EV004176","reportedCost":50000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100648311"},{"permit":"100648377","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"60 E RANDOLPH ST","workDescription":"REMOVE AND REPLACE REDUCER MOTOR AND ADD OVER SPEED SAFETY DEVICE ON 350FPM,C.S. OPERATION, 6 FLOORS, BELT MANNED PASSENGER LIFT IN GARAGE","reportedCost":31000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100648377"},{"permit":"100648266","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"1201 W ADAMS ST","workDescription":"REPLACE SUSPENSION ROPE AND SHEAVE ON TWO (2) 10-STOP,  2500LB.CAP, EWGT, 1-EAST & 2-WEST PASSENGER ELEVATORS. PURSUANT TO SCOPE OF WORK SUBMITTED.94043","reportedCost":21000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100648266"},{"permit":"100648265","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"222 S RACINE AVE","workDescription":"REPLACE SUSPENSION ROPES AND SHEAVES ON TWO (2) PASSENGERS ELEVATORS. ELEVATOR #1 7-STOP, 3500LB.CAP. ELEVATOR #2 6-STOP, 2500LB.CAP. PURSUANT TO SCOPE OF WORK SUBMITTED.EV019300","reportedCost":20000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100648265"},{"permit":"100648366","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"130 S CANAL ST","workDescription":"SUSPENSION  ROPE AND SHEAVE REPLACEMENT ON ONE (1) 3500LB.CAP, 11-STOP,EWGT SERVICE/PASSENGER ELEVATOR # 3. PURSUANT TO THE SCOPE OF WORK SUBMITTED. EV017017","reportedCost":10500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100648366"},{"permit":"100648267","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"2320 W PETERSON AVE","workDescription":"INSTALL NEW HOIST CABLES TO CAR #2 2000LB.CAP,150FPM,6-STOP PASSENGER ELEVATOR. PURSUANT TO SCOPE OF WORK SUBMITTED.","reportedCost":7989.5,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100648267"},{"permit":"100648375","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"1425 N DEARBORN ST","workDescription":"INSTALL NEW VALVE ASSEMBLY ON A 5-STOP, 1500LB.CAP,DIRECT HYDRAULIC PASSENGER ELEVATOR. PURSUANT TO THE SCOPE OF WORK SUBMITTED.EV001511","reportedCost":5991,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100648375"},{"permit":"100648291","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2016-05-04","address":"1033 W VAN BUREN ST","workDescription":"PURSUANT TO INSPECTOR # 371001 REQUEST,PERMIT TO BE ISSUED FOR FIREMAN SERVICE TESTING DUE TO THE ADDITION OF SMOKE DETECTORS TO ELEVATORS.EV018430","reportedCost":1500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100648291"}]}