{"trade":"elevator","week":"2023-W39","weekStart":"2023-09-25","weekEnd":"2023-10-01","fetchedAt":"2026-07-31T09:20:31.457Z","source":{"dataset":"ydr8-5enu","api":"https://data.cityofchicago.org/resource/ydr8-5enu.json","page":"https://data.cityofchicago.org/Buildings/Building-Permits/ydr8-5enu"},"ok":true,"error":null,"truncated":false,"permits":[{"permit":"101033129","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"3320 W HIRSCH ST","workDescription":"INSTALLATION OF (1) ONE HYDRAULIC PASSENGER ELEVATOR, 3000LBS CAPACITY @ 125FPM, 6 STOPS, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.","reportedCost":280000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033129"},{"permit":"101033155","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"1901 W MADISON ST","workDescription":"NEW DOOR OPERATOR AND CAR DOOR INSTALLATION ON THREE(3) 3500LB CAPACITY, (#7) 500FPM, 7-FLOOR,(#8, 9) 700FPM, 8-FLOOR, PASSENGER ELEVATORS, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV013853)","reportedCost":130000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033155"},{"permit":"101033106","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"1800 W BERENICE AVE","workDescription":"INSTALLATION OF (1) ONE EG PASSENGER ELEVATOR, 3500LBS CAPACITY @ 150FPM, 6 STOPS, 7 OPENINGS, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.","reportedCost":103078,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033106"},{"permit":"101033222","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"11601 W TOUHY AVE","workDescription":"CAB INTERIOR REPLACEMENT ON PASSENGER ELEVATORS #6 AND #7, PURSUANT TO THE SCOPE OF WORK ON LOCATION AT TIME OF INSPECTION. TERMINAL 5","reportedCost":100000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033222"},{"permit":"101033114","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"310 S PEORIA ST","workDescription":"DOOR OPERATOR REPLACEMENT ON TWO(2) 2500LB CAPACITY, PASSENGER (#1) 5-FLOOR, PASSENGER (#2) 6-FLOOR, 125FPM, ELEVATORS, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV009596)","reportedCost":95000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033114"},{"permit":"101033111","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"4939 N DAMEN AVE","workDescription":"INSTALLATION OF (1) ONE EG PASSENGER ELEVATOR, 2100LBS CAPACITY @ 150FPM, 5 STOPS, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDING ELEVATOR BUREAU INSPECTION.","reportedCost":88158,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033111"},{"permit":"101033200","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"2925 N SHEFFIELD AVE","workDescription":"INSTALLATION OF (1) ONE EWGD DUMBWAITER, 300LBS CAPACITY @ 50FPM, 2 STOPS, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.","reportedCost":79343,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033200"},{"permit":"101033121","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"6601 N RIDGE BLVD","workDescription":"INSTALLATION OF (1) ONE EG PASSENGER ELEVATOR, 2500LBS CAPACITY @ 150FPM, 2 STOPS, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.","reportedCost":61641,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033121"},{"permit":"101032240","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"325 N WELLS ST","workDescription":"REPLACEMENT OF ONE (1) GEARED HOIST MACHINE, 3500 LB.CAP, 400 FPM, 10-FLOOR, PASSENGER ELEVATOR # 3. PURSUANT TO THE SCOPE OF WORK SUBMITTED. EV009597","reportedCost":50000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101032240"},{"permit":"101033224","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"1538 W ESTES AVE","workDescription":"INSTALLATION OF (1) ONE HYDRAULIC SAVARIA TELECAB 17 HOME LIFT VERTICAL PLATFORM LIFT, 845LBS CAPACITY @ 20FPM, 2-#50 ROLLER CHAIN DRIVEN, 2 STOPS, SECOND FLOOR OVER UNIT HAS AN FLUSH FLOOR WHEN ON THE FIRST LANDING PROVIDE NOTIFIER (ALARM DURING OPERATION?)PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.","reportedCost":34765,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033224"},{"permit":"101033214","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"7743 S DAMEN AVE","workDescription":"INSTALLATION OF (1) ONE RESIDENTIAL VERTICAL PLATFORM LIFT AT THE REAR OF THE HOME, 750LBS CAPACITY @ 9FPM, SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION. (NOTE: LIFTS INSTALLED AT THE REAR OF THE HOME REQUIRE AN A.D.A. PHONE ON THE UNIT OR THE ASSISTANCE OF A CAREGIVER WITH A CELL PHONE TO OPERATE THE LIFT).","reportedCost":23773,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033214"},{"permit":"101033092","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"1738 W 34TH ST","workDescription":"INSTALLATION OF ONE(1) 750LB CAPACITY, VERTICAL PLATFORM LIFT, PURSUANT TO THE SCOPE OF WORK SUBMITTED","reportedCost":22929,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033092"},{"permit":"101033075","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"4743 S TALMAN AVE","workDescription":"INSTALLATION OF ONE(1) 750LB CAPACITY, VERTICAL PLATFORM LIFT, PURSUANT TO THE SCOPE OF WORK PLANS SUBMITTED.","reportedCost":22700,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033075"},{"permit":"101033210","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"10025 S AVENUE M","workDescription":"INSTALLATION OF (1) RESIDENTIAL VERTICAL PLATFORM LIFT AT THE FRONT OF THE HOME, 750LBS CAPACITY @ 9FPM, SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.","reportedCost":21298,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033210"},{"permit":"101033137","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"5549 S KEELER AVE","workDescription":"INSTALLATION OF (1) ONE RESIDENTIAL VERTICAL PLATFORM LIFT AT THE FRONT OF THE HOME, 750LBS CAPACITY @ 9FPM, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.","reportedCost":21294,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033137"},{"permit":"101033225","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"6912 S ROCKWELL ST","workDescription":"INSTALLATION OF (1) ONE RESIDENTIAL VERTICAL PLATFORM LIFT AT THE FRONT OF THE HOME, 750LBS. CAPACITY @ 9FPM, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.","reportedCost":17099,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033225"},{"permit":"101033205","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"4144 N SHERIDAN RD","workDescription":"MODERNIZATION OF (1) ONE EWGT PASSENGER ELEVATOR, 2000LBS CAPACITY, 6 STOPS, PURSUANT TO SCOPE OF WORK SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION (EV006052).","reportedCost":16345,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033205"},{"permit":"101033068","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"8226 S SANGAMON ST","workDescription":"INSTALLATION OF ONE(1) 400LB CAPACITY, STRAIGHT CHAIR LIFT, PURSUANT TO THE SCOPE OF WORK PLANS SUBMITTED.","reportedCost":16005,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033068"},{"permit":"101033067","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"3716 W 78TH ST","workDescription":"INSTALLATION OF ONE(1) 750LB CAPACITY, VERTICAL PLATFORM LIFT, LOCATED AT FRONT OF HOME, PURSUANT TO THE SCOPE OF WORK PLANS SUBMITTED.(100554492)","reportedCost":13789,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033067"},{"permit":"101033139","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"1742 W GARFIELD BLVD","workDescription":"INSTALLATION OF (1) ONE RESIDENTIAL VERTICAL PLATFORM LIFT AT THE REAR OF THE HOME, 750LBS CAPACITY @ 9FPM, PURSUANT TO PLANS SUBMITTED AND SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION. (NOTE: LIFTS INSTALLED AT THE REAR OF THE HOME REQUIRE AN A.D.A. PHONE ON THE UNIT OR THE ASSISTANCE OF A CAREGIVER WITH A CELL PHONE TO OPERATE THE LIFT.)","reportedCost":13500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033139"},{"permit":"101033150","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"1100 E 58TH ST","workDescription":"REPLACEMENT OF HOIST CABLES ON ONE(1) 2000LB CAPACITY, 4-FLOOR, 95FPM, PASSENGER ELEVATOR, PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV008162)RYERSON LAB D17","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033150"},{"permit":"101033152","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"8 E HURON ST","workDescription":"REPLACEMENT OF HOIST CABLES ON ONE(1) 3500LB CAPACITY, 27-FLOOR, 500FPM, PASSENGER ELEVATOR(#1), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(100670995)","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033152"},{"permit":"101033120","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"5855 S UNIVERSITY AVE","workDescription":"REMOVAL OF ONE(1) 750LB CAPACITY, VERTICAL WHEELCHAIR LIFT, PURSAUNT TO THE COPE OF WORK SUBMITTED.(EV016112)PRESIDENT'S HOUSE","reportedCost":2500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033120"},{"permit":"101033104","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"6700 S SOUTH SHORE DR","workDescription":"REPLACEMNENT OF TRAVELING CABLE ON ONE(1) 2000LB CAPACITY, 29-FLOOR, 500FPM, PASSENGER ELEVATOR(#1), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV006302)","reportedCost":0,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033104"},{"permit":"101033066","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"3716 W 78TH ST","workDescription":"REMOVAL OF ONE(1) 600LB CAPACITY, VERTICAL WHEELCHAIR LIFT, PURSAUNT TO THE SCOPE OF WORK SUBMITTED.(100554492)","reportedCost":0,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033066"},{"permit":"101033206","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"130 E RANDOLPH ST","workDescription":"REPLACEMENT OF GOVERNOR CABLE ON ONE(1) 3500LB CAPACITY, 22-FLOOR, 500FPM, PASSENGER ELEVATOR(#31), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV012241)","reportedCost":0,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033206"},{"permit":"101033220","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"11601 W TOUHY AVE","workDescription":"REPLACEMENT OF HOIST CABLES ON ONE(1) 2000LB CAPACITY, 7-FLOOR, 350FPM, PASSEMNGER ELEVATOR(#23 PARKING), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV012821)","reportedCost":0,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033220"},{"permit":"101033208","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"130 E RANDOLPH ST","workDescription":"REPLACEMENT OF GOVERNOR CABLE ON ONE(1) 3500LB CAPACITY, 37-FLOOR, 800FPM, PASSENGER ELEVATOR(#50), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV012241)","reportedCost":0,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033208"},{"permit":"101033079","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"111 W HURON ST","workDescription":"HOIST CABLE REPLACEMENT ON ONE(1) 2000LB CAPACITY, 14-FLOOR, 350FPM, PASSENGER ELEVATOR(#2), PURSUANT TO THE SCOPE OF WORK SUBMITTED.(EV002783)","reportedCost":0,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033079"},{"permit":"101033212","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-27","address":"321 N CLARK ST","workDescription":"WATER DAMAGE REPAIRS ON TWO(2) 3500LB CAPACITY, 14-FLOOR, 500FPM, PASSENGER ELEVATORS(#4-5), PURSUANT TO THE SCOPE OF WORK ON LOCATION AT TIME OF INSPECTION. (EV009275)","reportedCost":0,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101033212"},{"permit":"101032233","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-25","address":"111 E CHESTNUT ST","workDescription":"MODERNIZATION OF ONE (1) 2-FLOOR, 2500, 50 FPM, HYDRAULIC FREIGHT ELEVATOR #13. PURSUANT TO THE SCOPE OF WORK SUBMITTED. EV000911","reportedCost":166000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101032233"},{"permit":"101032320","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-25","address":"505 N MCCLURG CT","workDescription":"REPLACE HOIST ROPES ON EG PASSENGER ELEVATOR CAR 1, 3000LBS CAPACITY, 47 FLOORS, SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU IMSPECTION (A/P # 100169893).","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101032320"},{"permit":"101032282","permitType":"PERMIT - ELEVATOR EQUIPMENT","issueDate":"2023-09-25","address":"55 E MONROE ST","workDescription":"REPLACE HOIST ROPES ON EG PASSENGER ELEVATOR CAR 25, 3500LBS CAPACITY, 9 STOPS, SUBJECT TO CITY OF CHICAGO DEPT. OF BUILDINGS ELEVATOR BUREAU INSPECTION.","reportedCost":0,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101032282"}]}