{"trade":"fire-sprinkler","week":"2024-W04","weekStart":"2024-01-22","weekEnd":"2024-01-28","fetchedAt":"2026-07-31T09:29:40.681Z","source":{"dataset":"ydr8-5enu","api":"https://data.cityofchicago.org/resource/ydr8-5enu.json","page":"https://data.cityofchicago.org/Buildings/Building-Permits/ydr8-5enu"},"ok":true,"error":null,"truncated":false,"permits":[{"permit":"101030397","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-01-26","address":"707 W BRIAR PL","workDescription":"SELF-CERT 2019 CBC: ERECT A 4 STORY, 6 DWELLING UNIT MASONRY APARTMENT BUILDING WITH A BASEMENT, ROOF DECK, AND ACCESS STAIRS. TO INCLUDE A MASONRY TRASH ENCLOSURE, 6 HIGH WOOD AND WROUGHT IRON FENCE AND 6 CAR PARKING STALLS IN THE REAR, AS PER PLANS BUILDING TO HAVE AN AUTOMATIC FIRE SUPPRESSION SYSTEM THROUGHOUT, AS PER PLANS. STRUCTURAL PEER REVIEW INCLUDED.CONDITIONAL APPROVAL PER 14A-4-404.13., RELEASE OF FULL WRECKING PERMIT STILL PENDING.","reportedCost":2400000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101030397"},{"permit":"101041834","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-01-25","address":"3473 S ARCHER AVE","workDescription":"REVISION TO PERMIT #100924939 TO CHANGE FROM ONE SINGLE ELECTRICAL SERVICE TO 2 SEPARATE ELECTRICAL SERVICES: 1-PHASE, 600 AMP & 3-PHASE 600 AMP, IN AN EXISTING 3-STORY MIXED USE BUILDING EQUIPPED WITH A FIRE SPRINKLER SYSTEM. (OCCUPANCY R-2, M, TYPE III-A CONSTRUCTION)","reportedCost":20000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101041834"},{"permit":"101039702","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-01-24","address":"1014 W 14TH ST","workDescription":"SELF-CERT 2019 CBC: REVISION TO PERMIT 100940487 TO REMOVE THE SPRINKLER FROM THE SCOPE OF WORK FOR THE PREVIOUSLY ISSUED PERMIT FOR THE CONSTRUCTION OF A 1 STORY, 5483 SF CLUBHOUSE BUILDING. THE SPRINKLER WAS ORIGINALLY PROVIDED IN EXCESS OF CODE REQUIREMENTS. NO CHANGE TO PLAN LAYOUT, STRUCTURAL, OR MEP SYSTEMS. (OCCUPANCY A-3; CONSTRUCTION TYPE IIB)","reportedCost":3268241,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101039702"},{"permit":"101037932","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-01-22","address":"3134 N KENMORE AVE","workDescription":"SELF-CERT: CONSTRUCTION OF A NEW FULLY SPRINKLERED, 4,835 SF SINGLE FAMILY RESIDENCE ON A 50' X 125' COMBINED DOUBLE LOT. HOUSE HAS 2 LEVELS ABOVE GRADE AND HAS A BASEMENT -MORE THAN 50% BELOW GRADE. CONSTRUCTION ABOVE GRADE IS FRAME (TYPE V-A CONSTRUCTION), AS PER PLANS. STRUCTURAL PEER REVIEW. R-5 OCC.  CONDITIONAL APPROVAL PER 14A-4-404.13., RELEASE OF FULL WRECKING PERMIT STILL PENDING.","reportedCost":1060000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101037932"},{"permit":"101036980","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-01-22","address":"2227 W TAYLOR ST","workDescription":"SELF-CERT: INTERIOR ALTERATION TO AN EXIST. RESTAURANT - BOH AREA OF WORK (295 SQ. FT.). SELECTIVE DEMOLITION, SELECTIVE CONSTRUCTION. EXISTING HVAC TO REMAIN - PROVIDE NEW EXHAUST HOOD, ASSOCIATED DUCTWORKAND FIRE SUPPRESSION SYSTEM. SELECTIVE ELECTRICAL WORK - RECONFIGURE PER NEW ARCHITECTURAL PLANS. NO PLUMBING WORK. ALL PER PLANS.","reportedCost":20000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101036980"}]}