{"trade":"fire-sprinkler","month":"2024-05","monthStart":"2024-05-01","monthEnd":"2024-05-31","fetchedAt":"2026-07-31T10:26:43.736Z","source":{"dataset":"ydr8-5enu","api":"https://data.cityofchicago.org/resource/ydr8-5enu.json","page":"https://data.cityofchicago.org/Buildings/Building-Permits/ydr8-5enu"},"ok":true,"error":null,"total":32,"totalReportedCost":48634980,"costedCount":32,"largestReportedCost":23324000,"truncated":false,"permits":[{"permit":"101032971","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-29","address":"1801 S WABASH AVE","workDescription":"DDS 2019 CBRC: INTERIOR RENOVATION OF EXISTING 6 STORY MASONRY BEARING WALL BUILDING AND CONVERSION FROM 170 SRO UNITS INTO 100 ONE BEDROOM AND EFFICIENCY UNITS. ALL NEW INTERIOR PLUMBING AND ELECTRICAL AND MECHANICAL SYSTEMS. REPLACEMENT OF ALL EXISTING WINDOWS AND DOORS.- INTERIOR PAINTING AND FINISHES. UPGRADE ON THE EXISTING SPRINKLER SYSTEM. EXISTING MASONRY WILL BE POWER WASHED. EXISTING SINGLE PLY MEMBRANE WILL BE REMOVED AND REPLACED WITH NEW TPO ROOFING SYSTEM WITH UPDATED ROOF INSULATION. EXISTING ELEVATORS WILL REMAIN AND THE CABS INTERIOR WILL BE MODERNIZED. INTERIOR COURT YARD WILL RECEIVE NEW LANDSCAPING AND EQUIPMENT. (OCCUPANCY GROUP R-2; TYPE IIA CONSTRUCTION) CONSULTANT REVIEWER: GLOBETROTTERS ENGINEERING","reportedCost":23324000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101032971"},{"permit":"100994285","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-23","address":"1118 N CLEVELAND AVE","workDescription":"DDS 2019 CBC: NEW CONSTRUCTION MIXED INCOME MULTIFAMILY RESIDENTIAL BUILDING CONTAINING 9 UNITS IN A 3-STORY WALK-UP PORTION OF THE BUILDING AND 3 ATTACHED TWO-STORY TOWNHOME UNITS.  TYPE IIIB CONSTRUCTION (PRECAST CONCRETE AS THE PRIMARY STRUCTURAL SYSTEM), R-2 OCCUPANCY, SPRINKLERED BUILDING.  INCLUDES ALL ELECTRICAL, PLUMBING, MECHANICAL, FIRE PROTECTION FOR INTERIOR SCOPE OF WORK AND EXTERIOR IMPROVEMENTS, INCLUDING 9 PARKING SPACES IN A SHARED PARKING LOT, LANDSCAPING, AND ELECTRICAL. BUILDING 21 (OCCUPANCY GROUP: R-2; CONSTRUCTION TYPE IIIB)","reportedCost":6265906,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100994285"},{"permit":"100994281","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-23","address":"1117 N CAMBRIDGE AVE","workDescription":"DDS 2019 CBC: NEW CONSTRUCTION MIXED INCOME MULTIFAMILY RESIDENTIAL BUILDING CONTAINING 9 UNITS IN A 3-STORY WALK-UP PORTION OF THE BUILDING AND 3 ATTACHED TWO-STORY TOWNHOME UNITS.  TYPE IIIB CONSTRUCTION (PRECAST CONCRETE AS THE PRIMARY STRUCTURAL SYSTEM), R-2 OCCUPANCY, SPRINKLERED BUILDING.  INCLUDES ALL ELECTRICAL, PLUMBING, MECHANICAL, FIRE PROTECTION FOR INTERIOR SCOPE OF WORK AND EXTERIOR IMPROVEMENTS, INCLUDING PARKING SPACES IN A SHARED PARKING LOT, LANDSCAPING, AND ELECTRICAL. BUILDING 20 (OCCUPANCY GROUP: R-2; CONSTRUCTION TYPE IIIB) CONSULTANT REVIEWER: V3 COMPANIES OF IL","reportedCost":6247906,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100994281"},{"permit":"101048134","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-29","address":"8522 S LAFAYETTE AVE","workDescription":"SELF CERTIFICATION - PERSPECTIVES CHARTER SCHOOL - INTERIOR RENOVATION OF EXISTING INTERIOR SPACE INTO CLASSROOMS, LUNCHROOM, AND RESTROOMS. FULLY SPRINKLERED BUILDING - E-1 OCC.- TYPE 1 CONST.","reportedCost":3500000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101048134"},{"permit":"101041493","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-09","address":"2500 N HALSTED ST","workDescription":"SELF-CERT 2019 CBRC: BUILDOUT OF FINANCIAL SERVICES BRANCH LOCATION IN FIRST FLOOR TENANT SPACE IN EXISTING 4 STORY BUILDING. ALTERATION/REPLACEMENT OF FLOORING, CEILING, WALLS, MECHANICAL, ELECTRICAL, PLUMBING, SPRINKLER LAYOUT AS PER PLANS. NO STRUCTURAL SCOPE. (OCCUPANCY TYPES: B, R-2; CONSTRUCTION TYPE: IIIA)","reportedCost":2534000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101041493"},{"permit":"100948736","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-16","address":"3638 S WESTERN AVE","workDescription":"ERECT A 3 STORY, 6 RESIDENTIAL UNIT(A,B,C,D,E & F) TOWNHOME FRAME BUILDING WITH ATTACHED GARAGES, AS PER PLANS. TO BE FULLY SPRINKLERED.","reportedCost":1200000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=100948736"},{"permit":"101046523","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-16","address":"330 N WABASH AVE","workDescription":"RENOVATION OF AN EXISTING UNOCCUPIED 5,100 SQ. FT OFFICE INTERIOR SUITE ON A MULTI-TENANT FLOOR WITHIN AN EXISTING FULLY SPRINKLERED HIGH-RISE OFFICE BUILDING. SELECTIVE INTERIOR NON-STRUCTURAL DEMOLITION, (N) NON-STRUCTURAL PARTITIONS, DOORS, CEILINGS, LIGHTING, MILLWORK FINISHES, ELECTRICAL, PLUMBING, & HVAC. THERE ARE NO TELECOMMUNICATION EQUIPMENT ROOMS OVER 150SF INCLUDED IN THE SCOPE OF WORK.THERE IS NO STRUCTURAL WORK INCLUDED IN THE SCOPE OF WORK.","reportedCost":850000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101046523"},{"permit":"101050521","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-29","address":"3505 N GREENVIEW AVE","workDescription":"SELF -CERT 2019 ERECT A 3 STORY VA FRAME, FULLY SPRINKLERED, SINGLE FAMILY HOME WITH BASEMENT, FIRST FL COVERED DECK, THIRD FL COVERED DECK , FULLY 13D SPLINKER, PRIVATE ROOF DECK AND DETACHED GARAGE WITH ROOFDECK AND PERGOLAS, EXISTING OCCUPANCY R-5, PROPOUSE OCUPANCY R-5, TYPE OF CONSTRUCTION VA, PERPLANS","reportedCost":738150,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101050521"},{"permit":"101037509","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-07","address":"3720 N GREENVIEW AVE","workDescription":"INTERIOR RENOVATION OF 4 BATHROOMS, 3 POWDER ROOMS, AND 2 LAUNDRY ROOMS. ALTERATION OF MASTER BEDROOM SUITE TO INCREASE THE CLOSET SIZE MAKING AN ADDITIONAL SPRINKLER HEAD NECESSARY. REPLACE IN THE SAME LOCATION A FIRST FLOOR BUTLER'S PANTRY AND BASEMENT KITCHENETTE CABINETS, COUNTERTOPS, AND SINK. (CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS.)","reportedCost":500000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101037509"},{"permit":"101045348","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-07","address":"1140 N WELLS ST","workDescription":"SELF-CERT 2019 CBRC: INTERIOR ALTERNATIONS TO AN EXISTING COMMERCIAL SPACE OF APPROXIMATELY 1,680 SQUARE FEET INCLUDING A RESTAURANT, KITCHEN, SERVICE AREA, RESTROOM AND STORAGE ROOM ON THE FIRST FLOOR. CURRENT OCCUPANCY GROUP M, TYPE 1B CONSTRUCTION. PROPOSED OCCUPANCY GROUP A2, TYPE 1B CONSTRUCTION. THE EXISTING BUILDING IS FULLY-SPRINKLERED. THE SCOPE OF WORK SHALL CONSIST OF BUT IS NOT LIMITED TO THE FOLLOWING:NEW INTERIOR BUILD-OUT INCLUDING PARTITIONS, CEILINGS, LIGHTING, NEW FLOOR AND WALL FINISHES. ALTERATIONS TO THE EXISTING MECHANICAL, ELECTRICAL, AND PLUMBING SYSTEMS AS PER PLANS.NO STRUCTURAL WORK INCLUDED. AUTOMATIC SPRINKLER SYSTEM TO BE DESIGN-BUILD BY THE GENERAL CONTRACTOR.","reportedCost":500000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101045348"},{"permit":"101043655","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-24","address":"1604 N NORMANDY AVE","workDescription":"SELF-CERT 2019 CBRC: BASEMENT BUILD-OUT TO EXISTING 3 STORY MIX USE BUILDING, CONSTRUCT NEW OFFICE SPACES,B OCC.  AND RESIDENTIAL WORK OUT ROOM R-3 ( TENANTS ONLY ) AS PER PLANS, TYPE 3A CONSTRUCTION, BUILDING TO BE FULLY SPRINKLERED ( 1604 N NORMANDY AVE---6700-6720 W NORTH AVE )","reportedCost":492000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101043655"},{"permit":"101047439","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-20","address":"4543 S ST LAWRENCE AVE","workDescription":"2019 SELF CERT, INTERIOR AND EXTERIOR ALTERATIONS TO INCLUDE MECHANICAL, ELECTRICAL AND PLUMBING WORK TO SIX DWELLING UNITS.   DUPLEX 2 D.U. (BASEMENT & 1ST FL) AND BASEMENT & A NEW REAR WOOD PORCH AS PER PLANS. TYPE R2 OCCUPANCY CLASSIFICATION AND TYPE IIIA CONSTRUCTION TYPE. BUILDING TO BE SPRINKLERED NFPA13R.","reportedCost":450000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101047439"},{"permit":"101047187","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-03","address":"5050 W FOSTER AVE","workDescription":"SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS TO OFFICE AREA, TOILET ROOMS AND LOCKER ROOMS IN EXISTING MANUFACTURING FACILITY. NO CHANGE TO EXISTING USE OR AREA. 1-STORY -FULLY SPRINKLERD BUILDING. ( OCCUPANCY GROUP F-1; CONSTRUCTION TYPE II-B )","reportedCost":386823,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101047187"},{"permit":"101044084","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-29","address":"1132 W BLACKHAWK ST","workDescription":"SELF-CERT 2019 CBRC: INTERIOR ALTERATIONS TO AN EXISTING THIRD FLOOR BUSINESS USE FOOD AND FLAVORINGS LABORATORY SPACE AS PER PLANS. WORK TO INCLUDE REMOVAL AND REPLACEMENT OF EXISTING CEILING, SELECTED PARTITION OPENINGS AND SELECTED DOORS. NEW CONSTRUCTION OF NON-LOAD BEARING PARTITIONS, DOORS, CEILING, LIGHTING, INTERIOR FINISHES, POWER OUTLETS, DATA OUTLETS, PLUMBING FIXTURES, NEW DUCTWORK OUTLETS AND DISTRIBUTION DUCTWORK, SPRINKLER HEADS AND SECONDARY SPRINKLER PIPING, FIRE ALARM SYSTEM AND FURNISHINGS. NO STRUCTURAL WORK. NO CHANGE IN USE. (CONSTRUCTION TYPE: 1B; OCCUPANCY: B-BUSINESS OFFICE)","reportedCost":371000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101044084"},{"permit":"101029533","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-30","address":"835 E DREXEL SQUARE DR","workDescription":"SELF CERT 2019 CBRC FOR THE RENOVATION OF AN EXISTING SINGLE FAMILY RESIDENCE WITH A NEW DETACHED GARAGE. FULL SPRINKLER SYSTEM TO BE SUBMITTED FOR SEPARATE APPROVAL BY FIRE DEPT. OCCUPANCY IS R5 (NO CHANGE) AND TYPE III-A CONSTRUCTION. ELEVATOR INSTALLATION IS A SEPARATE SUBMISSION AND APPROVAL BY THE ELEVATOR BUREAU.","reportedCost":300000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101029533"},{"permit":"101048117","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-03","address":"225 W WACKER DR","workDescription":"** SELF-CERT PERMIT ** INTERIOR RENOVATION OF EXISTING TENANT OFFICE SUITE ON FLOOR 21. RENOVATION INCLUDES SELECTIVE DEMOLITION OF EXISTING SPACE IN PREPARATION FOR NEW INTERIOR PARTITIONS, CEILINGS, LIGHTING AND FINISHES AS WELL AS THE REWORKING OF HVAC, ELECTRICAL, SPRINKLERS AND FIRE ALARM. CURRENT USE: OFFICE. PROPOSED USE: OFFICE.","reportedCost":252000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101048117"},{"permit":"101043651","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-28","address":"1604 N NORMANDY AVE","workDescription":"SELF-CERT 2019 CBRC: BASEMENT BUILD-OUT TO EXISTING 3 STORY MIX USE BUILDING, CONSTRUCT NEW BARBER SHOP AT THE BASEMENT LEVEL PER PLANS, TYPE 3A CONSTRUCTION, BUILDING TO BE FULLY SPRINKLERED MECH. UNIT SUPPORT FRAMING PER PERMIT 101043655(1604 N NORMANDY AVE-- 6700-6720 W NORTH AVE )","reportedCost":191000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101043651"},{"permit":"101046346","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-16","address":"657 W ROSCOE ST","workDescription":"SELF CERT 2019 CBC NEW 3 STORY AND 2ND AND 3RD FLOOR REAR ADDITION TO AN EXISTING SINGLE FAMILY RESIDENCE AMD INTERIOR ALTERATIONS III-A CONSTRUCTION AS PER PLANS. FULLY SPRINKLERED BUILDING. EXCAVATION WORK CAN COMMENCE 30 DAYS AFTER CERTIFIED MAILING RECEIPT DATE OF 5-8-2024.","reportedCost":145000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101046346"},{"permit":"B101050259","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-17","address":"2505 W FARRAGUT AVE","workDescription":"**FIRE ALARM PERMIT****FIRE ALARM PERMIT****FIRE ALARM: INSTALLATION OF A REQUIRED FIRE ALARM SYSTEM, PER CITY OF CHICAGO BUILDING CODE SECTION 907, IN A CLASS R-2 RESIDENTIAL OCCUPANCY BUILDING. THE BUILDING IS FULLY PROTECTED BY A CITY OF CHICAGO APPROVED AUTOMATIC SPRINKLER SYSTEM. ELEVATOR RECALL IS INCLUDED IN THIS SCOPE OF WORK.","reportedCost":100000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050259"},{"permit":"101050064","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-17","address":"10 S WACKER DR","workDescription":"SELF-CERT 2019 CBRC - REMOVE GLASS PARTITION AND NON-REQUIRED EGRESS DOOR AND REPLACE WITH U419 FIRE RATED DRYWALL ASSEMBLY AS PER PLANS. (CONSTRUCTION TYPE IA ; OCCUPANCY CLASSIFICATION B) (FIRE SPRINKLER WORK UNDER SEPARATE PERMIT).","reportedCost":85000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101050064"},{"permit":"101042092","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-21","address":"2508 W MAYPOLE AVE","workDescription":"BUILDING PERMIT TO REPAIR EXTERIOR MASONRY WALLS, RESOLVE BUILDING VIOLATIONS, REPAIR WOOD BOWSTRING TRUSSES + REMOVE UN-PERMITTED PARTITIONS TO RESTORE ORIGINAL WAREHOUSE USE INTENTED FOR TENANT USE IN EXISTING 1 STORY MASONRY BUIDLING. (OCCUPANCY S-1, CONSTRUCTION TYPE 3-B) BUILDING IS FULLY SPRINKLERED ***CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS.","reportedCost":80000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101042092"},{"permit":"101045251","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-15","address":"4333 N WESTERN AVE","workDescription":"SPR CBC 2019 REVISION TO PERMIT NUMBER 101001614 TO REMOVE THE SPRINKLER SYSTEM PER EXEMPTION-2 OF SECTION 14B-9-903.2.8 AND PROVIDE FIRE AREAS PER SECTION 14B-7-707.3.10 FOR THE 4 STORY, 4 DWELLING UNIT MASONRY TYPE IIIA CONSTRUCTION TYPE AND R2 OCCUPANCY BUILDING. ADDRESS CODE MODIFICATIONS FOR LIGHT AND VENT, INTERCOURT LIGHT WELL SIZE AND REMOVE WINDOW AT SIDE WALL AS PER APPROVED ACAR AND AS PER PLANS.","reportedCost":28000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101045251"},{"permit":"101045203","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-02","address":"3636 N HAMILTON AVE","workDescription":"SPR 2019 CBC: REVISION TO PERMIT #101038225 TO REMOVE SPRINKLER SYSTEM  FROM NEW 2 STORY FRAME SINGLE FAMILY RESIDENCE WITH BASEMENT AND 2 CAR GARAGE WITH ROOF DECK (CURENT OCCUPANCY R-5, PROPOSED R-5, TYPE VA CONSTRUCTION).","reportedCost":25000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101045203"},{"permit":"101048114","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-21","address":"6453 S INGLESIDE AVE","workDescription":"SPR 2019 CBC: REVISION TO BUILDING PERMIT 101000696 TO REMOVE FIRE SPRINKLER SYSTEM AND TO ENCLOSED REAR STAIRS AS PER REVISED PLANS.**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT **","reportedCost":20000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101048114"},{"permit":"B101048799","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-13","address":"4700 N CENTRAL AVE","workDescription":"**FIRE ALARM PERMIT****FIRE ALARM SYSTEM**INSTALATION OF NOTIFICATION DEVICES IN ADDITION TO EXISTING FIRE SYSTEM IN EXISTING APPROVED FIRE ALARM SYSTEM. 100% SPRINKLERED.","reportedCost":10995,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101048799"},{"permit":"B101047437","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-10","address":"6701 W GRAND AVE","workDescription":"**FIRE ALARM PERMIT****FIRE ALARM PERMIT****FIRE ALARM: INSTALLATION OF A FIRE ALARM SYSTEM, PER CITY OF CHICAGO BUILDING CODE SECTION 907, IN A BUSINESS OCCUPANCY BUILDING. THE BUILDING IS FULLY PROTECTED BY A CITY OF CHICAGO APPROVED AUTOMATIC SPRINKLER SYSTEM.","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101047437"},{"permit":"B101048957","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-02","address":"232 S FRANKLIN ST","workDescription":"**FIRE ALARM PERMIT****FIRE ALARM PERMIT****FIRE ALARM: MODIFICATION OF AN EXISTING CITY OF CHICAGO APPROVED FIRE ALARM AND VOICE COMMUNICATION SYSTEM, PER CITY OF CHICAGO BUILDING CODE SECTION 13-76-050, TO ACCOMMODATE A RENOVATION ON THE 96TH FLOOR. ELEVATOR RECALL IS NOT INCLUDED IN THIS SCOPE. THE BUILDING IS FULLY PROTECTED BY A CITY OF CHICAGO APPROVED AUTOMATIC SPRINKLER SYSTEM.","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101048957"},{"permit":"B101049784","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-30","address":"230 S CLARK ST","workDescription":"**FIRE ALARM PERMIT****FIRE ALARM PERMIT****FIRE ALARM SYSTEMS**HALLWAY RENOVATIONS FOR FLOOR 23 FOR USE IN A REQUIRED CHICAGO APPROVED HIGH RISE FA SYSTEM. THE SPACE IS 100% SPRINKLERED.","reportedCost":6492,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101049784"},{"permit":"B101050577","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-20","address":"150 N WACKER DR","workDescription":"**FIRE ALARM PERMIT****FIRE ALARM SYSTEM**THIS IS FOR A NEW PARTIAL FLOOR TENANT ON FLOOR 23. THIS IS A REQUIRED CHICAGO APPROVED HIGH RISE FA SYSTEM. THE SPACE IS 100% SPRINKLERED.","reportedCost":6162,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050577"},{"permit":"B101045095","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-07","address":"230 S CLARK ST","workDescription":"**FIRE ALARM PERMIT****FIRE ALARM SYSTEM**WASHROOM RENOVATION FOR FLOOR 20 FOR USE IN A REQUIRED CHICAGO APPROVED HIGH RISE FA SYSTEM. THE SPACE IS 100% SPRINKLERED.","reportedCost":4196,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101045095"},{"permit":"B101050357","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-31","address":"1 E WACKER DR","workDescription":"**FIRE ALARM PERMIT**MODIFICATION OF AN EXISTING, CHICAGO APPROVED HIGH RISE (PER 907.2.12 HIGH-RISE BUILDINGS) VOICE EVACUATION/FIRE ALARM SYSTEM TO ACCOMMODATE TENANT RENOVATION. BUILDING IS FULLY SPRINKLERED.","reportedCost":675,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050357"},{"permit":"B101048737","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-03","address":"1 E WACKER DR","workDescription":"**FIRE ALARM PERMIT**MODIFICATION OF AN EXISTING, CHICAGO APPROVED HIGH RISE (PER 907.2.12 HIGH-RISE BUILDINGS) VOICE EVACUATION/FIRE ALARM SYSTEM TO ACCOMMODATE TENANT RENOVATION. BUILDING IS FULLY SPRINKLERED.","reportedCost":675,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101048737"}],"recordLimit":100}