{"trade":"garage","week":"2024-W19","weekStart":"2024-05-06","weekEnd":"2024-05-12","fetchedAt":"2026-07-31T09:27:24.924Z","source":{"dataset":"ydr8-5enu","api":"https://data.cityofchicago.org/resource/ydr8-5enu.json","page":"https://data.cityofchicago.org/Buildings/Building-Permits/ydr8-5enu"},"ok":true,"error":null,"truncated":false,"permits":[{"permit":"B101050894","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-12","address":"3423 N SEELEY AVE","workDescription":"60A FEEDER FROM MAIN 200A PANEL TO DETACHED GARAGE, 60A DISCONNECT AT GARAGE AND TESLA CHARGER (WALL CONNECTOR) INSTALLATION. 60A FEEDER WILL BE INSTALLED IN 3/4¿ EMT INSIDE AND OUTSIDE THE BUILDING AND 3/4¿¿ RMC UNDERGROUND BETWEEN THE HOUSE AND THE GARAGE.","reportedCost":2500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050894"},{"permit":"101035008","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-10","address":"1250 W 111TH PL","workDescription":"SPR 2019 CBC INTERIOR ALTERATIONS AND REMODELING OF AN EXISTING 2-STORY, 2-DWELLING UNITS RESIDENCE WITH BASEMENT. OCCUPANCY CODE R-5, CONSTRUCTION TYPE IIIA. REAR ADDITION TO ADDRESS VIOLATIONS. GARAGE REPAIRS TO ADDRESS VIOLATIONS PER PLANS","reportedCost":40000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101035008"},{"permit":"B200016821","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-10","address":"3511 W DICKENS AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X19'-0' '. HIP ROOF HEIGHT TO PEAK: 13'-0' '.","reportedCost":18100,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016821"},{"permit":"B200015973","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-10","address":"1942 W DICKENS AVE","workDescription":"TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 500 SQ. FT., LINTEL QTY. 1, MAX. LENGTH 4. LOCATION: BRICK GARAGE.","reportedCost":9300,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200015973"},{"permit":"B101050863","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-10","address":"7436 S TALMAN AVE","workDescription":"ELECTRICAL SERVICE AND EV INSTALLATION: THE FIRST ONE IS FOR THE INSTALLATION OF A NEW ELECTRICAL SERVICE WITH SPECIFIC COMPONENTS, AND THE SECOND ONE IS FOR THE INSTALLATION OF AN EV CHARGING STATION IN A DETACHED GARAGE.","reportedCost":3900,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050863"},{"permit":"B101050877","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-10","address":"8417 S KENTON AVE","workDescription":"INSTALL ELECTRIC FOR NEW GARAGE INCLUDING FIXTURES AND DEVICES   BB","reportedCost":1,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050877"},{"permit":"101048485","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-09","address":"4238 N CLAREMONT AVE","workDescription":"SELF CERTIFICATION- NEW CONSTRUCTION OF 2-STORY FRAME SINGLE FAMILY RESIDENCE WITH BASEMENT AND NEW 2-CAR FRAME GARAGE WITH ROOF DECK (R-5 OCCUPANCY, VA CONSTRUCTION) CONDITIONAL APPROVAL PER 14A-4-404.13., RELEASE OF FULL WRECKING PERMIT STILL PENDING.","reportedCost":600000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101048485"},{"permit":"101048085","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-09","address":"1715 W FOSTER AVE","workDescription":"SPR 2019 CBC. ERECT A NEW 2-STORY SINGLE FAMILY FRAME RESIDENCE W/ BASEMENT. NEW 2 CAR FRAME GARAGE WITH ROOF DECK. INSTALL 6 FEET HIGH WOOD AND IRON FENCE. ALL WORK AS PER PLANS.","reportedCost":350000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101048085"},{"permit":"101048086","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-09","address":"1719 W FOSTER AVE","workDescription":"SPR 2019 CBC. ERECT A NEW 2-STORY SINGLE FAMILY FRAME RESIDENCE W/ BASEMENT. NEW 2 CAR FRAME GARAGE WITH ROOF DECK. INSTALL 6 FEET HIGH WOOD AND IRON FENCE. ALL WORK AS PER PLANS.","reportedCost":350000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101048086"},{"permit":"101046530","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-09","address":"5432 S KENNETH AVE","workDescription":"SELF-CERT 2019 CBC: FULL BUILDING PERMIT FOR NEW 1-STORY SINGLE FAMILY RESIDENCE (BASEMENT + 1ST FLOOR ) (OCCUPANCY GROUP R-5,TYPE V-B CONSTRUCTION)- NEW FRAME DETACHED 2 CAR GARAGE- NEW FRONT STOOP & REAR TREATED WD DECK & STAIR- NEW CONC WALK & CONC APRON","reportedCost":300000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101046530"},{"permit":"B200016490","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-09","address":"2650 N LAKEVIEW AVE","workDescription":"CONCRETE MASONRY REPAIR / REPLACEMNT: 900SQ. FT., EXCAVATION = NO. LOCATION: PARKING GARAGE.","reportedCost":190525,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016490"},{"permit":"B200016591","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-09","address":"181 N DEARBORN ST","workDescription":"CONCRETE MASONRY REPAIR / REPLACEMNT: 30SQ. FT., EXCAVATION = NO. LOCATION: PARKING GARAGE.","reportedCost":151985,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016591"},{"permit":"B200016550","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-09","address":"11161 S TRUMBULL AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 24'-0' ' X20'-0' '. GABLE ROOF HEIGHT TO PEAK: 13'-0' '.","reportedCost":38950,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016550"},{"permit":"B200016302","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-09","address":"7552 S WOLCOTT AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X22'-0' '. HIP ROOF HEIGHT TO PEAK: 12'-0' '.","reportedCost":20000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016302"},{"permit":"B200016671","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-09","address":"2129 N KEDVALE AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X14'-0' '. HIP ROOF HEIGHT TO PEAK: 12'-6' '.","reportedCost":11800,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016671"},{"permit":"101040925","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-08","address":"6350 N GLENWOOD AVE","workDescription":"SPR 2019 CBC: ERECT NEW 4 STORY, III-A, 12DU APARTMENT BUILDING W/ROOFTOP STAIR ENCLOSURE, BALCONIES,  GROUND FLOOR RETAIL SPACE & 1 CAR PRIVATE GARAGE, 6 OUTDOOR PARKING SPACES,  W/ MASONRY TRASH ENCLOSURE AS PER PLANS (OCCUPANCY GROUPS R2, M) *STRUCTURAL PEER REVIEW*","reportedCost":1390000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101040925"},{"permit":"B200016589","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-08","address":"3001 N OAK PARK AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 24'-0' ' X20'-0' '. GABLE ROOF HEIGHT TO PEAK: 15'-0' '.","reportedCost":34439,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016589"},{"permit":"B200015542","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-08","address":"6096 N ORIOLE AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 30'-0' ' X20'-0' '. GABLE ROOF HEIGHT TO PEAK: 15'-0' '.","reportedCost":34400,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200015542"},{"permit":"B200016569","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-08","address":"7026 S BELL AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 20'-0' ' X19'-0' '. HIP ROOF HEIGHT TO PEAK: 13'-0' '.","reportedCost":33246,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016569"},{"permit":"B200015544","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-08","address":"5016 N NOTTINGHAM AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X18'-0' '. HIP ROOF HEIGHT TO PEAK: 12'-6' '.","reportedCost":32625,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200015544"},{"permit":"B200016295","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-08","address":"4237 N LINCOLN AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 20'-0' ' X30'-0' '. HIP ROOF HEIGHT TO PEAK: 12'-6' '.","reportedCost":32000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016295"},{"permit":"B200016575","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-08","address":"3540 N PULASKI RD","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 20'-0' ' X24'-0' '. GABLE ROOF HEIGHT TO PEAK: 14'-0' '.","reportedCost":31585,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016575"},{"permit":"B200015577","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-08","address":"9609 S GENOA AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 20'-0' ' X24'-0' '. GABLE ROOF HEIGHT TO PEAK: 12'-0' '.","reportedCost":31000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200015577"},{"permit":"B200016623","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-08","address":"8153 S KINGSTON AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X22'-0' '. HIP ROOF HEIGHT TO PEAK: 12'-0' '.","reportedCost":23000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016623"},{"permit":"B101050437","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-08","address":"311 N MORGAN ST","workDescription":"FURN/INST 30 AMP / 480 VOLT BKR IN ELEC PNL IN ELEC CLOSET + RUN RACEWAY FROM ELEC PNL TO DOCK AREA + CONDUIT RUN TO GARAGE ENT + INST A FUSED 30 AMP / 480 VOLT DISCONNECT ON LEFT SIDE OF GARAGE DOOR, WORK PERFD FOR EMILY HOTEL.","reportedCost":4000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050437"},{"permit":"101044852","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-07","address":"325 S RICHMOND ST","workDescription":"NEW 2-STORY, 2-UNIT RESIDENTIAL FRAME BUILDING, 5A CONSTRUCTION, W/ BASEMENT, OPEN REAR WOOD DECK, AND 2-CAR PRIVATE FRAME GARAGE, PER PLAN","reportedCost":350000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101044852"},{"permit":"101047936","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-07","address":"2640 N SPRINGFIELD AVE","workDescription":"SELF CERT 2019 CRBC; GUT REHAB TYPE V, 2-STORY, FRAME RESIDENCE WITH BASEMENT INCLUDING BASEMENT DIG-DOWN AND  REPAIRS TO EXISTING DETACHED 2- CAR GARAGE FOR DECONVERSION OF EXISTING 2-UNIT RESIDENTIAL BUILDING TO SINGLE FAMILY RESIDENCE. (OCCUPANCY GROUP R-5;TYPE VA CONSTRUCTION)","reportedCost":300000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101047936"},{"permit":"B200016292","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-07","address":"8732 S SANGAMON ST","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X20'-0' '. HIP ROOF HEIGHT TO PEAK: 13'-0' '.","reportedCost":28750,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016292"},{"permit":"B200015773","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-07","address":"4209 S ELLIS AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 5 KW. ARRAY OUTPUT: 5.88 KW.  LOCATION: SOLAR PV SYSTEM ON HOME AND GARAGE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #13-0674.","reportedCost":21432,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200015773"},{"permit":"B200016486","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-07","address":"1961 W GRANVILLE AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 20'-0' ' X18'-0' '. HIP ROOF HEIGHT TO PEAK: 15'-0' '.","reportedCost":19500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016486"},{"permit":"101046322","permitType":"PERMIT - WRECKING/DEMOLITION","issueDate":"2024-05-07","address":"3502 S UNION AVE","workDescription":"WRECK AND REMOVE A 2 STORY FRAME RESIDENCE AND A DETACHED FRAME GARAGE","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101046322"},{"permit":"B200013120","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-07","address":"6956 S WABASH AVE","workDescription":"REPAIR OR IN-KIND REPLACEMENT OF 0 PLUMBING FIXTURES AS DESCRIBED IN PERMIT APPLICATION.  INCLUDES REPAIR OR REPLACMENT OF PLUMBING PIPING.  INCLUDES REPAIR OR REPLACEMENT OF PLUMBING RISERS IN EXISTING CHASES.  LOCATIONS: 0 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 1 INTERIOR COMMON AREAS,  EXTERIOR WORK, BASEMENT, GARAGE, WATER HOSE SPIGOT.","reportedCost":5450,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200013120"},{"permit":"B101050450","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-07","address":"1238 W JACKSON BLVD","workDescription":"656-204-3131  EV LEVEL 2 WALL CONNECTOR PROPOSAL (X2) 1. FURNISH AND INSTALL (2) EV 60 AMP, 240 VOLT, 3 WIRE DEDICATED CIRCUIT. 2. FURNISH AND INSTALL (2) FUSED DISCONNECT. DISCONNECT WILL BE LOCATED IN THE EXISTING ELECTRICAL CLOSET. 3. PROPOSAL INCLUDES RUNNING (2) 3/4\" RIGID EMT CONDUIT INSTALLED FROM THE NEWLY INSTALLED DISCONNECT TO THE GARAGE PARKING SPACE. CONDUIT WILL BE SURFACE MOUNTED IN THE GARAGE. 4. CIRCUITRY WILL CONSIST OF (2) #6 AWG THHN COPPER CONDUCTORS AND (1) #10 AWG THHN GROUNDING CONDUCTOR FOR EACH CIRCUIT (X2) 5. INSTALL (2) CUSTOMER FURNISHED EV WALL CHARGERS. WALL CONNECTOR(S) WILL BE LOCATED ON THE BACK GARAGE OF THE PARKING SPOT. 7. FURNISH AND INSTALL (2) DISCONNECT SWITCH AS REQUIRED BY CODE. DISCONNECT SWITCH WILL BE INSTALLED NEXT TO THE WALL CONNECTOR. 8. PROVIDE (2) LOAD CALCULATION FOR THE UNITS INCLUDING THE NEW CHARGERS. $3,035.00","reportedCost":3035,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050450"},{"permit":"101045450","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2024-05-06","address":"3918 N PAULINA ST","workDescription":"SC CBC 2019 ERECT A 2 STORY TYPE VA FRAME SINGLE FAMILY RESIDENCE WITH A BASEMENT AND A NEW DETACHED TWO CAR GARAGE WITH A ROOF DECK AND AN ACCESS STAIRCASE, AS PER PLANS. R5 OCCUPANCY CLASSIFICATION. WRECKING PERMIT NUMBER 101043348 ISSUED ON MARCH 27, 2024, AND ADMINISTRATIVE ADJUSTMENT APPROVED ON APRIL 12, 2024.","reportedCost":600000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101045450"},{"permit":"101049432","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-06","address":"2445 W CULLOM AVE","workDescription":"SELF-CERT 2019 CBRC: 2ND FLOOR ADDITION, REAR 2 STORY ADDITION & REHAB TO EXISTING 1 STORY SINGLE FAMILY RESIDENCE WITH BASEMENT, REAR DECK AT 1ST STORY, DETACHED 2 CAR GARAGE AS PER PLAN (OCCUPANCY GROUP R-5, TYPE VA CONSTRUCTION).","reportedCost":180000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101049432"},{"permit":"B200016127","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-06","address":"3541 W 79TH PL","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X20'-0' '. HIP ROOF HEIGHT TO PEAK: 13'-0' '.","reportedCost":39508,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016127"},{"permit":"B200015212","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-06","address":"5318 W WINONA ST","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 27'-0' ' X22'-0' '. GABLE ROOF HEIGHT TO PEAK: 13'-6' '.","reportedCost":29800,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200015212"},{"permit":"101047226","permitType":"PERMIT - WRECKING/DEMOLITION","issueDate":"2024-05-06","address":"2216 N TALMAN AVE","workDescription":"WRECK AND REMOVE A 2 STORY FRAME RESIDENCE AND A DETACHED FRAME GARAGE","reportedCost":25650,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101047226"},{"permit":"B200016298","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-06","address":"3830 N PAULINA ST","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 26'-0' ' X19'-6' '. GABLE ROOF HEIGHT TO PEAK: 14'-0' '.","reportedCost":25000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016298"},{"permit":"B200015219","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-06","address":"1246 W 31ST ST","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 20'-0' ' X20'-0' '. HIP ROOF HEIGHT TO PEAK: 12'-6' '.","reportedCost":23600,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200015219"},{"permit":"B200016287","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-06","address":"5536 W WARWICK AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X22'-0' '. HIP ROOF HEIGHT TO PEAK: 12'-6' '.","reportedCost":22200,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016287"},{"permit":"101049021","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2024-05-06","address":"2122 W CHURCHILL ST","workDescription":"2019 CBRC:  REPLACE EXISTING REAR WOOD DECK, STAIRS, AND ROOF DECK ON EXISTING MASONRY 2-CAR GARAGE, AND ADD NEW PORCELAIN PAVERS, TRELLIS, GUARDRAILS, AND INSTALL NEW 5/8\" GYPSUM BOARD ON GARAGE CEILING AT EXISTING SFR (OCCUPANCY TYPE R-5, TYPE 3A CONSTRUCTION)","reportedCost":20000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101049021"},{"permit":"B200015812","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-06","address":"1711 N FREMONT ST","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 9.5 KW. ARRAY OUTPUT: 10.5 KW.  LOCATION: ROOF OF HOME & DETACHED GARAGE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0495.","reportedCost":10500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200015812"},{"permit":"101046953","permitType":"PERMIT - WRECKING/DEMOLITION","issueDate":"2024-05-06","address":"3339 N RIDGEWAY AVE","workDescription":"WRECK AND REMOVE A 3 STORY MASONRY MULTI UNIT RESIDENCE AND A DETACHED FRAME GARAGE","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101046953"},{"permit":"B101050384","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-06","address":"2612 W CHICAGO AVE","workDescription":"INSTALL (5) FEEDER SIDE TAPS WITH 50AMP BREAKERS FOR (5) NEMA 14-50 OUTLETS IN GARAGE FOR EV CHARGERS. EACH FEED WILL GO TO ITS RESPECTIVE UNIT.","reportedCost":7225,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050384"},{"permit":"B200016144","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-06","address":"2423 W THOMAS ST","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X20'-0' '. HIP ROOF HEIGHT TO PEAK: 12'-0' '.","reportedCost":6500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200016144"},{"permit":"B101050382","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2024-05-06","address":"2606 W CHICAGO AVE","workDescription":"INSTALL (4) FEEDER SIDE TAPS W ITH 50AMP BREAKERS FOR (4) NEMA 14-50 OUTLETS IN GARAGE FOR EV CHARGERS. EACH FEED W ILL GO TO ITS RESPECTIVE UNIT.","reportedCost":5780,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B101050382"},{"permit":"101050403","permitType":"PERMIT - EASY PERMIT PROCESS","issueDate":"2024-05-06","address":"6747 N OKETO AVE","workDescription":"WRECK AND REMOVE A DETACHED FRAME RESIDENTIAL GARAGE","reportedCost":4000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101050403"}]}