{"trade":"garage","week":"2025-W04","weekStart":"2025-01-20","weekEnd":"2025-01-26","fetchedAt":"2026-07-31T09:29:18.305Z","source":{"dataset":"ydr8-5enu","api":"https://data.cityofchicago.org/resource/ydr8-5enu.json","page":"https://data.cityofchicago.org/Buildings/Building-Permits/ydr8-5enu"},"ok":true,"error":null,"truncated":false,"permits":[{"permit":"B200411897","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-25","address":"4218 N TROY ST","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 20'-0' ' X30'-0' '. GABLE ROOF HEIGHT TO PEAK: 15'-0' '.","reportedCost":30000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411897"},{"permit":"B200404767","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-25","address":"9124 S AVALON AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X20'-0' '. GABLE ROOF HEIGHT TO PEAK: 13'-0' '.","reportedCost":12000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200404767"},{"permit":"101062154","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2025-01-24","address":"3719 N BOSWORTH AVE","workDescription":"SELF-CERT 2019 CRBC: NEW CONSTRUCTION OF A (1,089) SQ. FT., 3-STORY, TYPE VA FRAME, 35' HT., SINGLE-FAMILY RESIDENCE WITH PARTIAL (657) SQ. FT. 3RD STORY ROOF DECK, (131) SQ. FT. WOOD DECK, AND NEW (412) SQ. FT. 2-CAR, TYPE VA FRAME, DETACHED GARAGE WITH ROOF DECK. (OCCUPANCY GROUP R-5; TYPE VA CONSTRUCTION). FULL SPRINKLER SYSTEM.","reportedCost":415000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101062154"},{"permit":"101031816","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-01-24","address":"4713 W HURON ST","workDescription":"SPR 2019 CBRC. NEW REAR SECOND STORY DORMER ADDITION TO EXISTING TWO STORY BRICK SFR WITH BASEMENT (OCCUPANCY R-5, CONSTRUCTION VA) . INTERIOR ALTERATION AND REPAIRS INCLUDE ELECTRICAL, PLUMBING AND HVAC WORK. REPLACE EXIST REAR PORCH WITH NEW REAR FRAME PORCH. MASONRY REPAIRS AND LINTELS REPLACEMENT. NEW 6FT WROUGHT IRON FENCE. NEW TWO CAR FRAME GARAGE. ALL WORK AS PER PLANS.**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT **","reportedCost":150000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101031816"},{"permit":"B200411417","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-24","address":"1106 W WRIGHTWOOD AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: LOW-SLOPED (<2:12). INVERTER OUTPUT: 4.56 KW. ARRAY OUTPUT: 5.52 KW.   INCLUDES 20 KWH ENERGY STORAGE SYSTEM.  LOCATION: COACH HOUSE ROOF AND GARAGE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #20-0678.","reportedCost":28652.22,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411417"},{"permit":"B200403927","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-24","address":"1959 W OHIO ST","workDescription":"TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 347 SQ. FT., LINTEL QTY. 2, MAX. LENGTH 16. LOCATION: FRONT GARAGE SECTION.","reportedCost":27200,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200403927"},{"permit":"B200411090","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-24","address":"4119 W BELMONT AVE","workDescription":"TUCKPOINTING AND UNIT MASONRY REPAIR / REPLACEMENT: 600 SQ. FT., LINTEL QTY. 0, MAX. LENGTH 0. LOCATION: MASONRY REPAIR WORK ON EXISTING GARAGE.","reportedCost":23950,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411090"},{"permit":"B200411330","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-24","address":"5002 S RACINE AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X20'-0' '. GABLE ROOF HEIGHT TO PEAK: 14'-0' '.","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411330"},{"permit":"B200411933","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-24","address":"8630 S COLFAX AVE","workDescription":"LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 5 . LIGHTING OUTLETS: 5. SPECIFIC LOCATION: GARAGE AND REAR OF HOME.","reportedCost":2500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411933"},{"permit":"101061511","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-01-23","address":"6327 S ARTESIAN AVE","workDescription":"SELF-CERT 2019 CBRC: (OCCUPANCY GROUP R-5; TYPE IV CONSTRUCTION)FULL RENOVATION OF EXISTING 2 UNITS MASONRY BUILDING, EXPANSION OF EXISTING KITCHEN AT BOTH UNITS, ENCLOSE EXISTING SECOND FLOOR BALCONY. BASEMENT TO BE RESTORE TO ORIGINAL STATE.DEMOLITION OF EXISTING ROOF AND REBUILD NEW GABLE ROOF AND ROOF EXTENTION. AT EXISTING WOOD FRAME GARAGE. TO RECONCILE EXISTING BUILDING.","reportedCost":150000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101061511"},{"permit":"101052868","permitType":"PERMIT - WRECKING/DEMOLITION","issueDate":"2025-01-23","address":"13418 S AVENUE N","workDescription":"EMERGENCY WRECK AND REMOVAL OF A 1.5 STORY FRAME RESIDENCE AND ONE STORY DETACHED FRAME GARAGE","reportedCost":27580,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101052868"},{"permit":"B200411771","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-23","address":"77 W HURON ST","workDescription":"LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 4 . LIGHTING OUTLETS: 0. ELECTRIC VEHICLE SUPPLY EQUIPMENT:1 SPACES. SPECIFIC LOCATION: PARKING GARAGE.","reportedCost":16075,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411771"},{"permit":"B200411585","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-23","address":"3455 W 115TH ST","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 22'-0' ' X22'-0' '. GABLE ROOF HEIGHT TO PEAK: 15'-0' '.","reportedCost":12500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411585"},{"permit":"B200409829","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-23","address":"6256 N CICERO AVE","workDescription":"LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 10 CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 1. SPECIFIC LOCATION: GARAGE, EXTERIOR WALLS AND BASEMENT.","reportedCost":6000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200409829"},{"permit":"B200411475","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-23","address":"10520 S LONGWOOD DR","workDescription":"LINE VOLTAGE ELECTRICAL WORK. NEW PERMANENT 100 AMP SERVICE DISCONNECTING MEANS WITH 2 CIRCUITS. RECEPTACLE OUTLETS: 2 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: GARAGE.","reportedCost":2000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411475"},{"permit":"101061272","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2025-01-22","address":"3303 S SEELEY AVE","workDescription":"SPR 2019 CBC: NEW TWO STORY SINGLE FAMILY HOME  WITH BASEMENT, FRONT STAIR, AND DETACHED 2 CAR GARAGE AS PER PER PLANS (CONSTRUCTION TYPE 3A, OCCUPANCY TYPE R-5) **CERTIFIED PLANS CORRECTIONS: CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS **","reportedCost":350000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101061272"},{"permit":"101059115","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2025-01-22","address":"4246 N KIMBALL AVE","workDescription":"SPR 2019 CBC. NEW 2 -STORY SINGLE FAMILY RESIDENCE W/ BASEMENT AND DETACHED 2 CAR FRAME GARAGE. INSTALL 6 FEET HIGH WOOD & IRON FENCE. ALL WORK AS PER PLANS.","reportedCost":350000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101059115"},{"permit":"101061275","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2025-01-22","address":"3305 S SEELEY AVE","workDescription":"SPR 2019 CBC: NEW TWO STORY SINGLE FAMILY HOME  WITH BASEMENT, FRONT STAIR, AND DETACHED 2 CAR GARAGE AS PER PER PLANS ( CONSTRUCTION TYPE 3A, OCCUPANCY TYPE R-5) **CERTIFIED PLANS CORRECTIONS: CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS **","reportedCost":350000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101061275"},{"permit":"101049443","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2025-01-22","address":"2219 N KIMBALL AVE","workDescription":"SPR 2019 CBC: NEW CONSTRUCTION OF COACH HOUSE ACCESSORY DWELLING UNIT (ADU) OVER A PROPOSED 2-CAR GARAGE (OCCUPANCY GROUP R-5, TYPE V-A CONSTRUCTION)","reportedCost":150000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101049443"},{"permit":"B200399058","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-22","address":"4500 S TROY ST","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 13.44 KW. ARRAY OUTPUT: 18.4 KW.  LOCATION: SOLAR ROOF PRIMARY/GARAGE INSTALL 46 MODULES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-1231.","reportedCost":63000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200399058"},{"permit":"101058337","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-01-22","address":"2220 W CHARLESTON ST","workDescription":"SELF-CERT 2019 CBRC: REMOVE EXISTING GARAGE AND ERECT NEW MASONRY 2-CAR GARAGE WITH ROOF TOP DECK, STAIRS AND STEEL PERGOLA TO EXISTING 1.5 MASONRY SINGLE FAMILY RESIDENCE","reportedCost":45000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101058337"},{"permit":"101060806","permitType":"PERMIT - WRECKING/DEMOLITION","issueDate":"2025-01-22","address":"1301 N ASHLAND AVE","workDescription":"WRECK AND REMOVE A 4 STORY MASONRY MIXED USE BUILDING AND A METAL GARAGE/SHED","reportedCost":30000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101060806"},{"permit":"101060651","permitType":"PERMIT - WRECKING/DEMOLITION","issueDate":"2025-01-22","address":"4538 N OAKLEY AVE","workDescription":"WRECK AND REMOVE A 2 STORY FRAME RESIDENCE AND A DETACHED FRAME GARAGE","reportedCost":20000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101060651"},{"permit":"101060902","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2025-01-22","address":"1950 W LAWRENCE AVE","workDescription":"SPR 2019 CBRC: REVISION TO PERMIT NUMBER 100968475; REVISED EAST WALL CONSTRUCTION OF A 12-UNIT RESIDENTIAL BUILDING MIXED-USE BUILDING. OCCUPANCY R-2; TYPE III-A CONSTRUCTION 5-STORY BUILDING W/GROUND FLOOR MERCANTILE SPACE AND PRIVATE GARAGE.","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101060902"},{"permit":"B200411729","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-22","address":"5213 S LOCKWOOD AVE","workDescription":"LINE VOLTAGE ELECTRICAL WORK. ADD 1 CIRCUITS TO EXISTING 100 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. ELECTRIC VEHICLE SUPPLY EQUIPMENT:1 SPACES. SPECIFIC LOCATION: GARAGE.","reportedCost":3750,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411729"},{"permit":"B200411770","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-22","address":"1060 W FRY ST","workDescription":"LINE VOLTAGE ELECTRICAL WORK. REPAIR OR ALTER DEVICES ON EXISTING CIRCUITS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. ELECTRIC VEHICLE SUPPLY EQUIPMENT:1 SPACES. SPECIFIC LOCATION: GARAGE.","reportedCost":2160,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411770"},{"permit":"B200411059","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-22","address":"3764 N WILTON AVE","workDescription":"WRECK AND REMOVE DETACHED MASONRY GARAGE, NO REPLACEMENT. LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), EXTERIOR WORK, GARAGE DEMOLITION.","reportedCost":2000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411059"},{"permit":"101060426","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-01-21","address":"2235 N KIMBALL AVE","workDescription":"REAR BUILDING: PROPOSED 1ST FLOOR NORTH SIDE PORCH, ATTACHED 1 PARKING SPACE GARAGE ADDITION,  2 SPACE PARKING PAD, INTERNAL RENOVATIONS TO DECONVERT AN EXISTING 2 STORY/2 UNIT RESIDENCE TO COACH HOUSE (PER ADU ORDIANCE), PER PLANS.","reportedCost":150000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101060426"},{"permit":"B200409673","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-21","address":"1000 W WASHINGTON BLVD","workDescription":"LINE VOLTAGE ELECTRICAL WORK. ADD 21 CIRCUITS TO EXISTING 400 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 21 . LIGHTING OUTLETS: 0. ELECTRIC VEHICLE SUPPLY EQUIPMENT:21 SPACES. SPECIFIC LOCATION: PARKING GARAGE LEVEL 1, LEVEL 2, HEATED GARAGE.","reportedCost":30000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200409673"},{"permit":"B200411014","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-21","address":"2442 N AUSTIN AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 3.48 KW. ARRAY OUTPUT: 0.00492 KW.  LOCATION: GARAGE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #23-0387.","reportedCost":19302,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411014"},{"permit":"B200411665","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-21","address":"2453 W ERIE ST","workDescription":"LINE VOLTAGE ELECTRICAL WORK. ADD 1 CIRCUITS TO EXISTING 200 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. ELECTRIC VEHICLE SUPPLY EQUIPMENT:1 SPACES. SPECIFIC LOCATION: GARAGE.","reportedCost":2448,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411665"},{"permit":"B200411364","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-20","address":"9 W WALTON ST","workDescription":"LINE VOLTAGE ELECTRICAL WORK. ADD 2 CIRCUITS TO EXISTING 1000 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 2 . LIGHTING OUTLETS: 0. ELECTRIC VEHICLE SUPPLY EQUIPMENT:4 SPACES. SPECIFIC LOCATION: PARKING GARAGE.","reportedCost":36300,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411364"},{"permit":"B200406962","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-01-20","address":"2447 N CENTRAL AVE","workDescription":"NEW DETACHED WOOD FRAME GARAGE. DIMENSIONS AND SETBACKS PER APPLICATION. BUILDING OUTSIDE DIMENSIONS: 19'-10' ' X19'-3' '. HIP ROOF HEIGHT TO PEAK: 13'-7' '.","reportedCost":12922,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200406962"}]}