{"trade":"hvac","month":"2025-11","monthStart":"2025-11-01","monthEnd":"2025-11-30","fetchedAt":"2026-07-31T09:34:26.697Z","source":{"dataset":"ydr8-5enu","api":"https://data.cityofchicago.org/resource/ydr8-5enu.json","page":"https://data.cityofchicago.org/Buildings/Building-Permits/ydr8-5enu"},"ok":true,"error":null,"total":40,"totalReportedCost":9102042,"costedCount":39,"largestReportedCost":1425900,"truncated":false,"permits":[{"permit":"101075824","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-25","address":"333 W WACKER DR","workDescription":"SELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO OFFICE SUITE 1800 TO INCLUDE DEMO, NEW PARTITIONS, DOORS, CEILINGS, ELECTRICAL, PLUMBING AND HVAC AS PER PLANS. NO STRUCTURAL WORK. B-BUSINESS, 1A CONSTRUCTION.","reportedCost":1425900,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101075824"},{"permit":"101075832","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-25","address":"333 W WACKER DR","workDescription":"SELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO OFFICE SUITE 1400 TO INCLUDE DEMO, NEW PARTITIONS, DOORS, CEILINGS, ELECTRICAL, PLUMBING AND HVAC AS PER PLANS. NO STRUCTURAL WORK. B-BUSINESS, 1A CONSTRUCTION.","reportedCost":1309500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101075832"},{"permit":"101076080","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-25","address":"1107 N SACRAMENTO AVE","workDescription":"SELF-CERT 2019 CBRC: INTERIOR REMODEL AND VIOLATION REMEDIATION FOR EXISTING 3-STORY, TYPE IIIA MASONRY, 38' HT., 3-UNIT RESIDENTIAL BUILDING WITH UNFINISHED BASEMENT INCLUDING NEW HVAC AND NEW 400 AMP ELECTRICAL SERVICE UPGRADE (OCCUPANCY GROUP R-5; TYPE IIIA CONSTRUCTION).","reportedCost":950000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076080"},{"permit":"101073672","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2025-11-05","address":"3440 S PARNELL AVE","workDescription":"BUILD A NEW MASONRY RESIDENCE WITH 2 DWEELING UNITS: INCLUDING ARCHITECTURAL, ELECTRICAL, HVAC AND PLUMBING WORK.","reportedCost":800000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101073672"},{"permit":"101075174","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-04","address":"500 W MADISON ST","workDescription":"SELF CERT 2019 CBRC: STRUCTTURAL PEER REVIEW INCLUCED. INTERIOR RENOVATION OF EXISTING 25TH FLOOR BUSINESS USE SPACE. DEMOLITION SCOPE INCLUDES REMOVAL OF EXISTING INTERIOR PARTITIONS, FINISHES, CEILINGS, LIGHTING, SELECT HVAC, AND ELECTRICAL ITEMS. NEW WORK INCLUDES NEW INTERIOR PARTITIONS, DOORS AND STOREFRONTS, FINISHES, CEILINGS, LIGHTING, SELECT HVAC, AND ELECTRICAL ITEMS. NO CHANGE IN USE OR OCCUPANCY. B-BUSINESS, IA CONSTRUCTION.","reportedCost":614000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101075174"},{"permit":"101076056","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-13","address":"300 S WACKER DR","workDescription":"SELF CERT 2019 CBRC: INTERIOR ALTERATIONS TO OFFICE SUITE 2424 TO INCLUDE DEMO, NEW PARTITIONS, DOORS, ELECTRICAL AND HVAC AS PER PLANS. NO STRUCTURAL WORK. B-BUSINESS, 1A CONSTRUCTION.","reportedCost":500000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076056"},{"permit":"101075060","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2025-11-06","address":"10117 S WOOD ST","workDescription":"SELF-CERT 2019 CBC: A NEW BUILDING PERMIT APPLICATION FOR THE CONSTRUCTION OF A NEW ONE-STORY BRICK VENEER SINGLE-FAMILY HOME WITH A BASEMENT AND AN ATTACHED TWO-CAR GARAGE - THE TRADES INVOLVED WILL BE CARPENTRY, MASONRY, HVAC, ELECTRICAL, AND PLUMBING - THE OCCUPANCY IS GROUP R-5 AND THE CONSTRUCTION TYPE IS VA. *****THIS BUILDING PERMIT # 101075060 WILL REPLACE THE FORMER AND EXPIRED BUILDING PERMIT # 100927645 WITH THE EXACT SAME SCOPE OF WORK*****","reportedCost":500000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101075060"},{"permit":"101073340","permitType":"PERMIT - NEW CONSTRUCTION","issueDate":"2025-11-12","address":"7200 S DR MARTIN L KING JR DR","workDescription":"SELF-CERT 2019 CCC: NEW CONSTRUCTION OF A TWO (2)-STOREY, TWO (2)-UNIT APT. BUILDING ON A VACANT LOT AS PER THE ATTACHED PERMIT DRAWINGS - SCOPE INCLUDES ASSOCIATED CARPENTRY, MASONRY, MECHANICAL (HVAC), ELECTRICAL, AND PLUMBING TRADE WORK - THE BUILDING OCCUPANCY CLASSIFICATION IS GROUP R-5; THE BUILDING CONSTRUCTION TYPE IS V-A; AND THE REAR PORCH CONSTRUCTION IS WOOD.","reportedCost":475000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101073340"},{"permit":"101076590","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-28","address":"10820 S BEVERLY AVE","workDescription":"SELF-CERT 2019 CBRC; FIRE RESTORATION AND MINOR RENOVATION WORK TO THE EXISTING 2-STORY, BRICK TYPE IIIB SPLIT-LEVEL, SINGLE FAMILY RESIDENCE, GROUP R-5. THE WORK IS TO INCLUDE;- REPLACE ALL INTERIOR GYP. BOARD, SMOKE DAMAGED INSULATION, FIXTURES & FINISHES THROUGH-OUT.- RENOVATE 2ND FLOOR FOR PRIMARY SUITE WITH ADDITIONAL BATHROOM.- CLEAN HVAC SYSTEM, REPLACE ELECTRICAL LIGHTS & SWITCHES, ALONG WITH PLUMBING MODIFICATIONS.","reportedCost":430000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076590"},{"permit":"101072009","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-21","address":"536 E 42ND ST","workDescription":"SPR 2019 CBC: RENOVATION INCLUDES REPLACEMENT OF INTERIOR FINISHES, PARTIAL INTERIO RECONFIGURATION, NEW EXTERIOR PAINT AND FINISHES, REPLACEMENT OF EXISTING PLUMBING FIXTURES, REPLACEMENT OF LIGHT FIXTURES AND ELECTRICAL DEVICES (EXISTING ELECTRICAL SERVICE TO REMAIN) AND REPAIRS TO THE EXISTING HVAC SYSTEM. AND NEW MASONRY TRASH ENCLOSURE. EXISTING ROOF TO REMAIN. ALL AS PER PLANS IN AN EXISTING BUILDING (CONSTRUCTION TYPE 3A, OCCUPANCY TYPE A-3)","reportedCost":404000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101072009"},{"permit":"101075084","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-24","address":"7212 S LUELLA AVE","workDescription":"RENOVATE EXISTING 2,410 SF 2-STORY SINGLE FAMILY RESIDENCE WITH A NEW DORMERS IN THE ATTIC.1 STORY REAR ADDITION AND A NEW 1-STORY 2-CAR GARAGE. ALL NEW HVAC, ELECTRICAL AND PLUMBING. NEW WINDOW INSTALLATION. REPAIR EXISTING TILE ROOF WITH DORMER ADDITION.","reportedCost":250000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101075084"},{"permit":"101074170","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-28","address":"3035 W WASHINGTON BLVD","workDescription":"INTERIOR REMODELING OF 3 DU IN EXISTING 3 DU 3 STORY BRICK BUILDING NEW ELECTRICAL, PLUMBING AND HVAC,","reportedCost":210000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074170"},{"permit":"101070859","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-10","address":"2158 W BARRY AVE","workDescription":"REVISION TO PERMIT #101058960 TO REVISE THE MECHANICAL SHEET (M101) PER THE REQUEST AND INSTRUCTION OF THE HVAC INSPECTOR FOR FINAL INSPECTIONS ONLY. UPDATES INCLUDE RELOCATING THE FURNACE FROM ROOFTOP TO MECHANICAL CLOSET, UPDATES TO THE FURNACE/CONDENSER/REFRIGERANT SCHEDULE TO REFLECT THE NEW FURNACE EQUIPMENT, AND TO ADD MAKEUP AIR FOR THE KITCHEN EXHAUST HOOD. NOTE THAT ALL ROUGH INSPECTIONS HAVE BEEN APPROVED","reportedCost":200000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101070859"},{"permit":"101073544","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-13","address":"1123 W WOLFRAM ST","workDescription":"THE SCOPE OF WORK INVOLVES THE INTERIOR REMODELING AND RENOVATION OF AN EXISTING TWO-FLAT RESIDENTIAL BUILDING, WHICH IS TO REMAIN THE SAME USE AND OCCUPANCY. MOST OF THE EXISTING NON-LOAD BEARING WALLS ARE TO REMOVED. ALL LOAD BEARING WALLS ARE TO REMAIN. ALL PLUMBING AND ELECTRICAL EQUIPMENT IS TO BE REMOVED. THE WORK PROPOSES NEW LAYOUTS FOR THE TWO UNITS. THE EXISTING BASEMENT SLAB ON GRADE WILL BE REMOVED AND SOIL DUG OUT TO PROVIDE A NEW, LOWER SLAB AND INCREASED HEAD HEIGHT FOR CODE COMPLIANCE. STRUCTURAL: THE BASEMENT SLAB AND COLUMNS WILL BE REPLACED, WHILE THE REMAINDER OF THE WOOD FRAMING WILL REMAIN WITH STRUCTURAL REINFORCEMENT WHERE NEEDED. A NEW SHEAR WALL WILL BE ADDED.MEP: ALL NEW MEP EQUIPMENT, EXCEPT FOR THE UPPER UNIT'S FURNACE WHICH IS TO BE REUSED. NEW 1-1/2\" WATER SERVICE INTO BUILDING, UNDER SEPARATE PERMIT. THE EXISTING REAR STAIRCASE AND ENCLOSED PORCH ARE NOT IN SCOPE AND ARE TO REMAIN.","reportedCost":175000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101073544"},{"permit":"101076367","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-21","address":"5700 S DUSABLE LAKE SHORE DR","workDescription":"SELF CERT 2019 CBC: INTERIOR ALTERATIONS TO EXISTING MUSEUM EXHIBITION SPACE FOR NEW NUMBERS IN NATURE EXHIBIT TO INCLUDE DEMO, NEW WALLS, NEW ELECTRICAL CIRCUITING & HVAC MODIFICIATIONS AS PER PLANS (OCCUPANCY A-3, TYPE IB CONSTRUCTION)","reportedCost":156543,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101076367"},{"permit":"101074438","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-12","address":"10001 S PULASKI RD","workDescription":"THE SCOPE OF WORK INCLUDES REMOVAL OF EXISTING BLEACHERS AND INSTALLATION OF NEW RETRACTABLE BLEACHER SYSTEMS WITHIN THE SCHOOL GYMNASIUM. MINOR ELECTRICAL MODIFICATIONS REQUIRED FOR POWER AND CONTROL OPERATIONS (NO ADDITIONAL STRUCTURAL, PLUMBING, HVAC WORK IS REQUIRED.)**CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS)**","reportedCost":125000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074438"},{"permit":"101074526","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-24","address":"520 W 129TH PL","workDescription":"SPR 2019 CBC. INTERIOR ALTERATIONS TO EXISTING ONE STORY MASONRY SFR WITH BASEMENT (IIIA CONSTRUCTION, R-5 OCCUPANCY) INCLUDING ELECTRICAL, HVAC AND PLUMBING. REPLACE EXISTING GARAGE WITH NEW FRAME TWO CAR GARAGE ON EXISTING CONCRETE SLAB. NEW 50 FT OF 6 FT HIGH WOOD FENCE. ALL WORK AS PER PLANS. CERTIFIED PLAN CORRECTIONS.","reportedCost":80000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074526"},{"permit":"101074997","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-07","address":"5701 S FRANCISCO AVE","workDescription":"SELF-CERT 2019 CBRC; INTERIOR RENOVATION OF AN EXISTING 1-STORY BRICK, TYPE IIIB, SINGLE FAMILY RESIDENCE, GROUP R-5, WITH BASEMENT. THE WORK IS TO INCLUDE:- OPEN PLAN WITH UPDATED KITCHEN& BATH AND 2-BEDROOMS AT 1ST FLOOR.- FAMILY ROOM, 2 BEDROOMS & 2ND BATHROOM AT BASEMENT.- UPGRADED ELECTRICAL, NEW HVAC & PLUMBING MODIFICATIONS.- REBUILT WOOD STAIRS TO EXISTING PORCH & 6 FT. HIGH STEEL & WOOD FENCE (42 L.F.).","reportedCost":78000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074997"},{"permit":"101069469","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-13","address":"11419 S PRAIRIE AVE","workDescription":"SELF-CERT 2019 CCC: INTERIOR RENOVATION FOR AN EXISTING 2-STORY SINGLE-FAMILY HOME, ONLY, AS PER THE ATTACHED PERMIT DRAWINGS SET - NO INCREASE IN BULK - TRADE WORK INCLUDES MASONRY, HVAC, ELECTRICAL, AND PLUMBING - THE CONSTRUCTION TYPE IS III-A AND THE OCCUPANCY CLASSIFICATION IS R-5.","reportedCost":72000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101069469"},{"permit":"101075970","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-24","address":"1539 S CHRISTIANA AVE","workDescription":"SELF-CERT 2019 CBRC; RENOVATE THE EXISTING 2-STORY MASONRY, TYPE IIIB, GROUP R-5, 2-UNIT APARTMENT BUILDING WITH BASEMENT. WORK TO INCLUDE:- 2 OPEN PLAN APARTMENTS WITH NEW KITCHENS, BATHROOMS & 3 BEDROOMS IN EACH.- NEW FURNACES, UPGRADED ELECTRICAL & PLUMBING MODIFICATIONS PER PLANS.- REINFORCE EXISTING REAR WOOD PORCH & INSTALL 6'-0\" HEIGHT O.I. FENCE (75 L.F.).","reportedCost":67000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101075970"},{"permit":"101067142","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-13","address":"4350 S FAIRFIELD AVE","workDescription":"SPR 2019-CBRC: INTERIOR REMODELING OF 2 APARTMENTS REPLACE DRYWALL AND FINISHES, NEW HVAC SYSTEM, PLUMBING AND ELECTRIC WORK ALSO REPLACE EXISTING FRONT WOOD PORCH SAME SIZE AND LOCATION AND REPLACE EXISTING REAR WOOD STAIRS AT EXISTING 2 STORY BRICK BUILDING, TYPE IIB CONSTRUCTION**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT **","reportedCost":42600,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101067142"},{"permit":"101038767","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-17","address":"3359 S INDIANA AVE","workDescription":"CURRENT USE/OCCUPANCY IS R5 (MULTI-UNIT RESDENTIAL) AND WILL REMAIN R5. UNFINISH BASEMENT CONVERSION TO APARTMENT UNIT PER PLANS (ALL NEW WALL PARTITIONS ARE NON-BEARING). NEW HVAC SYSTEM, NEW ELECTRIC PANEL, WIRING, RECEPTACLES, SWITCHES & LIGHT FIXTURES, TWO NEW BATHROOMS & NEW WINDOWS PER PLAN","reportedCost":40000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101038767"},{"permit":"101073528","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-18","address":"2125 W DEVON AVE","workDescription":"2019 CBRC:INTERIOR ALTERATION TO REPLACE BASEMENT CONCRETE FLOOR WITH NO UNDERPINNING AT 2 STORY MIXED USE BUILDING AS PER PLAN. NO ELECTRICAL, NO HVAC WORK.","reportedCost":30000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101073528"},{"permit":"101066632","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-13","address":"4054 W PATTERSON AVE","workDescription":"2019 CBRC: REVISION TO PERMIT # 101033689 TO CHANGE HVAC SYSTEM AS PER PLANS (OCCUPANCY GROUP R-5; TYPE V-A CONSTRUCTION)**CERTIFIED CORRECTIONS SUBJECT TO FIELD INSPECTIONS & AUDIT **","reportedCost":25000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101066632"},{"permit":"101065161","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-07","address":"1150 W TAYLOR ST","workDescription":"SPR 2019 CRBC CONVERTING EXISTING SECOND STORY RESIDENTIAL UNIT ABOVE AN EXISTING COMMERCIAL SPACE (TATOO PARLOR) TO A COMMERCIAL SPACE (TATOO PARLOR), PROVIDE OUTSIDE AIR INTAKE TO EXISTING 2ND FLR FURNACE & NO WORK TO MECHANICAL SYSTEMS.  INSTALLING EMERGENCY LIGHTS, EXIT SIGNS, AND PLUMBING FIXTURES.  (B OCCUPANCY USE, TYPE 5A CONSTRUCTION) PER PLANS  **CERTIFIED PLANS CORRECTIONS: CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS **","reportedCost":20000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101065161"},{"permit":"B200409783","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-26","address":"5301 N WINTHROP AVE","workDescription":"REPAIR/REPLACEMENT AFFECTING 2 SYSTEMS :   1 CENTRAL FURNACE(GOODMAN GM9S920804CN EXISTIN FURNACE ROOM)  1 OTHER AIR HANDLING EQUIPMENT(GOODMAN GSXN3N4810 AT GRADE REPALCE EXISITNG A/C UNIT) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S),  EXISTING FURNANCE ROOM.","reportedCost":15000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200409783"},{"permit":"101075057","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-25","address":"545 E 88TH PL","workDescription":"SELF-CERT 2019 CBRC: REVISION TO THE PREVIOUS BUILDING PERMIT # 101044073 FOR THE LEGALIZED RENOVATION OF AN EXISTING TWO-STORY BUNGALOW HOME WITH DORMERS, AS PER THE ATTACHED PERMIT DRAWING SET - INCLUDES CARPENTRY, MECHANICAL (HVAC), ELECTRICAL, AND PLUMBING WORK - THE OCCUPANCY CLASSIFICATION GROUP IS R-5 AND THE CONSTRUCTION TYPE IS III-A.","reportedCost":15000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101075057"},{"permit":"101073118","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-21","address":"5318 S KENNETH AVE","workDescription":"SPR 2019 CBRC: RESIDENTIAL MECHANICAL WORK TO SUPPLEMENT PERMIT 100864144 SUBMITTED BY A SEPARATE ARCHITECT. INCLUDES FURNACE UNITS AND ASSOCIATED DUCTS AND GRILLES FOR SUPPLY AND RETURN AIR FOR 3 UNITS WITHIN THE BUILDING. CERTIFIED PLAN CORRECTIONS.","reportedCost":15000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101073118"},{"permit":"101069967","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-17","address":"3720 S UNION AVE","workDescription":"REVISION TO PERMIT ISSUE 100951834. INTERIOR REMODELING 2DU WITH BASEMENT. BASEMENT FRAMING REVISIONS PER PLANS. REMOVED POWDER ROOM PLUMBING FIXTURES AT FIRST AND SECOND FLOOR AND CAP PIPES. MOVE FURNACE FROM BASEMENT TO SECOND FLOOR. ELECTRIC, HVAC, PER PERMIT ISSUED PLANS. REVISIONS ARE BUBBLED.(CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS)","reportedCost":15000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101069967"},{"permit":"B200446054","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-05","address":"2603 W NORTH AVE","workDescription":"REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS :   1 CENTRAL FURNACE(HVAC REPLACEMENT IN THE FURNACE ROOM) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), 1 INTERIOR COMMON AREAS,  STOREFRONT.","reportedCost":15000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200446054"},{"permit":"B200444868","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-20","address":"3215 W DIVISION ST","workDescription":"SCOPE: NONSTRUCTURAL INTERIOR ALTERATION OF EXISTIG OFFICE TO REMOVE NONLOAD BEARING PARTITION SECTIONS, UPGRADE ELECTRICAL 200 AMP SERVICE AND REWIRE, INSTALL HVAC DUCTWORK, PATCH AND REPAIR DRYWALL. LOCATIONS: 0 RESIDENTIAL UNIT(S), 1 NON-RESIDENTIAL UNIT(S), INTERIOR DRYWALL, ELECTRICAL OUTLETS.","reportedCost":14900,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200444868"},{"permit":"B200450282","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-13","address":"656 E BOWEN AVE","workDescription":"NEW HEAT PUMP OR REFRIGERATION EQUIP., ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), EXTERIOR WORK,  FURNACE IN BASEMENT AND CONDENSER IN THE YARD.","reportedCost":10000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200450282"},{"permit":"B200446811","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-07","address":"8508 S WALLACE ST","workDescription":"SCOPE: NONSTRUCTURAL INTERIOR ALTERATION TO BASEMENT INCLUDING NEW FULL BATHROOM AND REPLACEMENT OF FURNACE AND DUCTWORK. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), BASEMENT ONLY","reportedCost":5500,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200446811"},{"permit":"101074565","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-19","address":"1353 N LONG AVE","workDescription":"SELF-CERT: REVISION TO PERMIT #101068769 TO REFLECT THE AS-BUILD CONDITIONS FOR CHANGES IN THE BASEMENTLAYOUT, AS PER ARCHITECT'S PLAN, IN EXISTING 2 STORY BRICK AND FRAME BUILDING WITH BASEMENT. THE SCOPE OF WORK INCLUDES: ARCHITECTURAL, PLUMBING, HVAC AND ELECTRIC. CURRENT & PROPOSED USE: 2 DWELLING UNITS.","reportedCost":5000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101074565"},{"permit":"B200449016","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-07","address":"7353 S BLACKSTONE AVE","workDescription":"REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS :   2 BOILER - HOT WATER(RHEEM 40 GAL , XG40T06EC36U1, BASEMENT)  2 CENTRAL FURNACE(ACIQ 80,000 BTU 90%, AQ-GD9S800804BX, BASEMENT, 2ND FLOOR) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 2 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S),  2ND FLOOR AND BASEMENT.","reportedCost":4000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200449016"},{"permit":"B200449372","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-30","address":"2104 W WASHINGTON BLVD","workDescription":"SCOPE: NONSTRUCTURAL INTERIOR REPLACEMENT OF INTERIOR DRYWALL ONLY, NO ELECTRICAL, PLUMBING OR HVAC WORK INCLUDED. LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S), 1ST FL..","reportedCost":3800,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200449372"},{"permit":"B200449557","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-11","address":"2239 N CLYBOURN AVE","workDescription":"REPAIR/REPLACEMENT AFFECTING 1 SYSTEMS :   1 CENTRAL FURNACE(CARRIER MODEL :C3125A49257) . ELECTRICAL WORK UNDER THIS PERMIT = NO . LOCATIONS: 1 RESIDENTIAL UNIT(S), 0 NON-RESIDENTIAL UNIT(S),  UTILITY ROOM IN UNIT 2239-2.","reportedCost":3000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200449557"},{"permit":"B200450543","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-18","address":"544 W 104TH ST","workDescription":"LINE VOLTAGE ELECTRICAL WORK. ADD 1 CIRCUITS TO EXISTING 20 AMP SERVICE DISCONNECTING MEANS. RECEPTACLE OUTLETS: 1 . LIGHTING OUTLETS: 0. SPECIFIC LOCATION: FURNACE ROOM.","reportedCost":1200,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200450543"},{"permit":"101069226","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-11-19","address":"5231 S INDIANA AVE","workDescription":"SPR 2019 CBRC: REVISION OF PREVIOUS PERMIT: #100987650; HVAC & ELECTRICAL MODIFICATION ONLY. INTERIOR RENOVATIONS IN (12) D.U. W/ DUPLEX DN TO BSMT & PORCH/FACADE REPAIRS ON 3-STORY MASONRY BLDG. (OCCUPANCY GRP. R-2, TYPE III-A CONSTRUCTION); PER PLANS (CONDITIONAL PERMIT SUBJECT TO FIELD INSPECTIONS)","reportedCost":99,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101069226"},{"permit":"B200451799","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-11-21","address":"943 N CROSBY ST","workDescription":"OTHER ADMINISTRATIVE CHANGE ASSOCIATED WITH PERMIT 101069801. DETAILS: REVISION TO PERMIT # 101069801 TO REDESIGN HVAC SYSTEM.  ADMINISTRATIVE FILING ONLY. NO SUBSTANTIVE CHANGE TO SCOPE OF PERMIT 101069801.","reportedCost":null,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200451799"}],"recordLimit":100}