{"trade":"solar","week":"2025-W08","weekStart":"2025-02-17","weekEnd":"2025-02-23","fetchedAt":"2026-07-31T10:16:28.581Z","source":{"dataset":"ydr8-5enu","api":"https://data.cityofchicago.org/resource/ydr8-5enu.json","page":"https://data.cityofchicago.org/Buildings/Building-Permits/ydr8-5enu"},"ok":true,"error":null,"truncated":false,"permits":[{"permit":"B200413696","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-21","address":"855 N LECLAIRE AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 11.4 KW. ARRAY OUTPUT: 13.12 KW.   INCLUDES 10 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF OF HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #19-0021.","reportedCost":37510,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413696"},{"permit":"B200414096","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-21","address":"2515 N RUTHERFORD AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 7.6 KW. ARRAY OUTPUT: 9.84 KW.   INCLUDES 10 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF OF HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #19-0021.","reportedCost":32320,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200414096"},{"permit":"B200413214","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-21","address":"2324 W 111TH PL","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 12.3 KW.  LOCATION: ROOF OF HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #19-0021.","reportedCost":26205,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413214"},{"permit":"B200413338","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-21","address":"3138 N NEWCASTLE AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 7.6 KW. ARRAY OUTPUT: 6.56 KW.   INCLUDES 10 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF OF HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #19-0021.","reportedCost":20849,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413338"},{"permit":"B200413188","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-21","address":"6342 S HONORE ST","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 5 KW. ARRAY OUTPUT: 7.695 KW.  LOCATION: ROOF OF HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #19-0021.","reportedCost":14666,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413188"},{"permit":"B200414173","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-21","address":"8619 S BURNHAM AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 4.8 KW. ARRAY OUTPUT: 6.48 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":11856,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200414173"},{"permit":"101060152","permitType":"PERMIT - RENOVATION/ALTERATION","issueDate":"2025-02-20","address":"8915 S LOOMIS ST","workDescription":"SPR 2019 CBRC: INSTALLATION OF A 46.56 KW SOLAR PV SYSTEM USING (97) HANWHA PV MODULES WITH 480 WATTS OF POWER EACH ON ROOF. AS PER PLANS","reportedCost":174000,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=101060152"},{"permit":"B200414148","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-20","address":"8622 S MAY ST","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 7.8 KW. ARRAY OUTPUT: 10.53 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":19266,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200414148"},{"permit":"B200414147","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-20","address":"7304 S ABERDEEN ST","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 6.3 KW. ARRAY OUTPUT: 8.2 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":15580,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200414147"},{"permit":"B200414115","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-20","address":"5945 S WASHTENAW AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 5 KW. ARRAY OUTPUT: 6.56 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":12464,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200414115"},{"permit":"B200413870","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"4829 N WINTHROP AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 5.16 KW. ARRAY OUTPUT: 5.04 KW.   INCLUDES 20 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #14-0235.","reportedCost":33860,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413870"},{"permit":"B200413367","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"7638 S CREGIER AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 6.08 KW. ARRAY OUTPUT: 6.8 KW.  LOCATION: ROOFTOP - PRINCIPAL STRUCTURE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0735.","reportedCost":32994,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413367"},{"permit":"B200411786","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"2944 W 86TH PL","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 10 KW. ARRAY OUTPUT: 11.05 KW.  LOCATION: HOUSE ROOF. ICC DISTRIBUTED GENERATION INSTALLER CERT. #14-0400.","reportedCost":31149,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200411786"},{"permit":"B200413950","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"10930 S HOYNE AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 12.3 KW. ARRAY OUTPUT: 16.605 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":30381,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413950"},{"permit":"B200413999","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"1452 W 72ND ST","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 11.7 KW. ARRAY OUTPUT: 15.17 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":28823,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413999"},{"permit":"B200413974","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"2543 N MEADE AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 6.9 KW. ARRAY OUTPUT: 9.315 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":17043,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413974"},{"permit":"B200413877","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"3332 N OVERHILL AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 6.3 KW. ARRAY OUTPUT: 8.2 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":15580,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413877"},{"permit":"B200413876","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"10941 S PARNELL AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 5.1 KW. ARRAY OUTPUT: 6.885 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":12597,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413876"},{"permit":"B200413917","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"3935 N ORIOLE AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 4.5 KW. ARRAY OUTPUT: 6.075 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":11115,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413917"},{"permit":"B200413993","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"9939 S PRINCETON AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 4.1 KW. ARRAY OUTPUT: 5.33 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":10127,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413993"},{"permit":"B200413119","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-19","address":"2653 W GEORGE ST","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 0.32 KW. ARRAY OUTPUT: 0.00602 KW.  LOCATION: ROOFTOP. ICC DISTRIBUTED GENERATION INSTALLER CERT. #24-0198.","reportedCost":4214,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413119"},{"permit":"B200413887","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-18","address":"4418 S ALBANY AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 9.1 KW. ARRAY OUTPUT: 11.89 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":22591,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413887"},{"permit":"B200413799","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-18","address":"7740 S MARYLAND AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 6.6 KW. ARRAY OUTPUT: 8.91 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":16302,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413799"},{"permit":"B200413856","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-18","address":"7417 S CHAPPEL AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: LOW-SLOPED (<2:12). INVERTER OUTPUT: 3.8 KW. ARRAY OUTPUT: 4.51 KW.  LOCATION: SOLAR PANEL INSTALL, 11 MODULES, 3.8KW/AC, UNIT 2. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-1231.","reportedCost":15200,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413856"},{"permit":"B200413622","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-18","address":"7336 S HARVARD AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: SLOPED (2:12 TO 5:12). INVERTER OUTPUT: 2.28 KW. ARRAY OUTPUT: 0.00246 KW.  LOCATION: MAIN HOUSE. ICC DISTRIBUTED GENERATION INSTALLER CERT. #23-0387.","reportedCost":9750,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413622"},{"permit":"B200413798","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-18","address":"9349 S WOODLAWN AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 3.3 KW. ARRAY OUTPUT: 4.455 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":8151,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413798"},{"permit":"B200413880","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-18","address":"3240 N NARRAGANSETT AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: STEEP (>5:12). INVERTER OUTPUT: 3.2 KW. ARRAY OUTPUT: 4.1 KW.   INCLUDES 13.5 KWH ENERGY STORAGE SYSTEM.  LOCATION: ROOF PLANES. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-0817.","reportedCost":7790,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413880"},{"permit":"B200413701","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-18","address":"7423 S EBERHART AVE","workDescription":"INSTALL SOLAR PANELS ON ROOF OF PRINCIPAL BUILDING. ROOF TYPE: LOW-SLOPED (<2:12). INVERTER OUTPUT: 0.32 KW. ARRAY OUTPUT: 0.00731 KW.  LOCATION: ROOFTOP. ICC DISTRIBUTED GENERATION INSTALLER CERT. #24-0198.","reportedCost":5117,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413701"},{"permit":"B200413562","permitType":"PERMIT – EXPRESS PERMIT PROGRAM","issueDate":"2025-02-17","address":"9719 S AVENUE J","workDescription":"INSTALL SOLAR PANELS ON ROOF OF ACCESSORY BUILDING. ROOF TYPE: LOW-SLOPED (<2:12). INVERTER OUTPUT: 5.76 KW. ARRAY OUTPUT: 8.2 KW.  LOCATION: ROOFTOP SOLAR PANEL INSTALL, 20 MODULES, 5.76KW/AC. ICC DISTRIBUTED GENERATION INSTALLER CERT. #18-1231.","reportedCost":23040,"cityRecordUrl":"https://data.cityofchicago.org/resource/ydr8-5enu.json?permit_=B200413562"}]}